13. Unmounting the top module
MiR1000 Shelf Lift User Guide (en) 12/2020 - v.2.1 ©Copyright 2019-2020: Mobile Industrial Robots A/S.
213
8.
Gently pull the cables out of the top compartments, and remove the lifting device. The
top module is now removed from the robot.
MiR1000 will enter Emergency stop without a top module or dummy plugs
connected to the top electrical interfaces. Contact your distributor for more
information.
After you have finished completing the maintenance that required you to remove MiR Shelf
Lift, you can mount the top module again by following the above instructions in the reverse
order.
When mounting MiR Shelf Lift, make sure to face the side with white Emergency stop cable
to the right side of the robot.
NOTICE
When mounting the top module to the robot, make sure that no cables are
pinched beneath the top module. This may damage the cables, and prevent
the top module from working correctly.