13. Unmounting the top module
MiR250 Shelf Carrier User Guide (en) 03/2021 - v.1.4 ©Copyright 2021: Mobile Industrial Robots A/S.
215
13. Unmounting the top module
If you need to access the robot from the top, you must unmount MiR Shelf Carrier 250. This
can be required when troubleshooting issues or replacing robot components.
WARNING
Removing covers from the robot exposes parts connected to the power supply,
risking damage to the robot from a short circuit and electrical shock to
personnel.
•
Before removing any covers, turn off the robot, and disconnect the
battery—see
Disconnecting the battery on page 74
.
To unmount the top module, follow these steps:
1.
Unscrew the six screws at the front and rear of the top module's top plate with a TX20
Torx screwdriver.