26
Installation on to the Back Face of a Shower Cubicle or Laminated
Panel
The building-in depth for the integral wall mounting bracket assembly is
58 mm
. The
integral wall mounting bracket assembly can be used to install the shower control into a
shower cubicle or laminated panel of between
4
and
21 mm
. The building-in depth
calculation must include the final thickness of plaster and tiles.
1.
Follow the shower control installation
procedure as for
“Solid, Dry-lined,
Stud Partition or Dry Partition Wall
Structures”: instructions 1.
to
4.
inclusive.
2.
Cut a circular hole in the panel measuring
124 mm
in diameter.
3.
Using the wall mounting bracket as a
template, mark the position of the two
smaller diameter fixing holes on the
flanges of the bracket. These should be
at an angle of 45°.
4.
Drill the two fixing holes.
5.
Fix the shower control to the wall
mounting bracket using the two M4 x 16
mm screws provided.
6.
Feed the shower control through the
opening in the panel and fix to the panel
with the two M4 x 30 mm fixing screws.
7.
Follow the shower control installation
procedure as for
“Solid, Dry-lined,
Stud Partition or Dry Partition Wall
Structures”: instructions 11.
to
18.
inclusive to complete the installation.