Reversed Inlet Supplies
Mira CombiForce 415 shower controls are supplied with inlet connections
hot left,
cold
right
and
bottom outlet
. The Mira CombiForce 415B is supplied with inlet connections
hot left
,
cold right
and
top outlet
as
standard
.
Both shower controls are fitted with a single sequential control knob.
The shower control is turned off by turning the control knob fully clockwise. The correct
sequence of operation is anticlockwise movement of the control knob followed by: Cold
Warm
Hot water. If the sequence is: Hot
Warm
Cold water, then the hot and
cold water supplies have been reversed.
To correct reversed hot and cold inlet supplies proceed as follows:
1.
Prise off the concealing cap, remove the control knob retaining screw/plastic
temperature override stop and the control knob.
2.
Remove the hub. Turn the spindle one full turn (360
o
). Refit the hub.
3.
Refit the control knob, (with the override button at the bottom), the control knob
retaining screw/plastic override stop and the concealing cap.
4.
Check the maximum temperature. Adjust if necessary (refer to
Commissioning
).
5.
Turn the knob fully clockwise to the shut off position.
6.
This completes the procedure for "
Reversed Inlet Supplies
".
Control Knob
Hub
Plastic Override
Stop
Concealing Cap
Control Knob
Retaining Screw