35
Customer Fault Diagnosis
The trouble shooting information tabled below gives details on what you can do as a
user should you encounter difficulties whilst operating the shower.
Note!
Should these remedies prove to be unsuccessful in solving your problem, contact
your installer for further advice.
Key for applicability column
A
- Instantaneous gas heated showers.
B
- Unvented mains pressure showers.
C
- Mains pressurised, instantaneous hot water, heated from thermal store showers.
Section
10
Fault Diagnosis
Shower
insufficiently hot.
Wide temperature
fluctuations from
shower when no
other draw-off is
being made.
(a) Maximum
temperature
incorrectly set.
Reset adjustable
maximum
temperature.
(b) Heater not set on
maximum hot.
(c) Flow rate still too
high.
Consult heater
instructions or contact a
CORGI registered
installer.
Fit 9 l/min flow regulator
between shower control
and hose.
Contact your local water
supplier or a CORGI
registered installer.
(d) See also
“Shower
insufficiently
hot”
.
Remedy
Malfunction
Cause
A B C
Check and clean inlet
strainers.
(a) Insufficient flow
rate causing the
heater to cycle on
and off.
(b) Insufficient water
pressure causing
the heater to
cycle on and off.
(c) Heater not fully
modulating.
Contact a CORGI
registered installer. See
Installation
Requirements
.