37
Remedy
Malfunction
Cause
(a) Heater appliance
not igniting due to
insufficient mains
pressure.
Contact the local water
supplier or a CORGI
registered installer.
Open valve.
Wait until reheated.
Refer to
“Wide
temperature
fluctuations”
.
Wait for hot water to
reheat.
Renew cartridge. Refer
to the section
Maintenance:
“Cartridge Renewal”
.
Renew ‘O’ seals with
Service Pack.
(c) Product hot or cold
isolating valve not
fully open.
(d) Hot water run out.
(a) Insufficient flow
rate.
(b) Hot water supply
temperature
dropped.
(a) Pipework not
flushed before
connecting shower
control. (Internal ‘O’
seals damaged).
(b) Cartridge or inlet
strainer ‘O’ seals
damaged.
No hot water
available
Shower starts warm
and then runs cool.
Shower control
cannot be shut off.
No flow or low flow
from shower head.
(a) Supply stop valve
turned down or off.
(b) Inlet Strainers
blocked.
(c) Hose or handset
blocked.
Open valve.
Clean or renew.
Clear blockage. If
necessary renew hose
or handset.
(d) Spray plate
blocked.
Remove and clean.
A B C
Check and clean inlet
strainers.
(e) Inlet strainer
blocked.
Shower force too
strong.
Fit 9 l/m flow regulator.
High pressure supplies.
(b) Heater appliance
not igniting due to
appliance fault.
Contact a CORGI
registered installer.