26
Control Assembly
Important!
The Yellow Lugs on the Flow
Control must be in the fully clockwise
(off) position in order to fit the Control
Assembly.
Note!
The Flow Control Lugs on pre 2006
models are Black.
1.
Rotate the Temperature Knob fully
clockwise and carefully pull it off.
2.
Remove the Grey Control Bearing.
3.
Pull off the Flow Lever.
4.
Remove the Flow Lever Adapter.
Important! The Lever Retainer
must not be removed.
5.
Carefully unclip the Concealing Plate
from the Backplate.
Note!
Use a screwdriver in the cutout
to assist separation.
6.
Fit the Backplate to the Shower
Control and secure with the two
Securing Screws (removed from the
Building-in Shroud). Make sure that
the Foam Seal is fully compressed.
Do not overtighten.
7.
With the cutout at the bottom,
locate the Concealing Plate over the
Shower Control, engage the crosses
in the Concealing Plate with the
square recesses in the Backplate,
and push firmly until the Concealing
Plate clicks into position.
Backplate
Concealing
Plate
Flow Lever Adapter
Flow Lever
Grey Control Bearing
Temperature Knob
Flow Control
‘Yellow Lugs’
Lever Retainer
Note!
If the knob does not come off, rotate it
fully anticlockwise, pull on the Temperature
Knob while slowly rotating it clockwise until it
disengages.
Summary of Contents for DISCOVERY
Page 42: ...42 NOTES ...
Page 43: ...43 NOTES ...