28
REVERSED INLET SUPPLIES
The Discovery Shower Control is supplied with inlet connections
Hot-Left
,
Cold-Right
and
Bottom-Outlet
as standard. If the hot and cold water supply pipes have been
reversed during installation the following procedure must be performed.
1.
Isolate the hot and cold water supplies.
2.
Operate the Flow Lever and Temperature Knob to drain any residual water.
3.
Rotate the Temperature Knob fully clockwise and carefully pull it off.
Note!
If the knob does not come off, rotate it fully anticlockwise, pull on the
Temperature Knob while slowly rotating it clockwise until it disengages.
4.
Remove the Grey Control Bearing.
5.
Pull off the Flow Lever.
6.
Remove the Flow Lever Adapter.
7. Exposed Models only (illustrated):
a) Carefully remove the Locking Ring.
b) Rotate the Lever Retainer clockwise to disengage and remove.
8.
Built-in Models only:
a) Carefully unclip the Concealing Plate from the Backplate.
Important! The Lever Retainer must not be removed.
Note!
Use a screwdriver in the cutout to assist separation.
b) Unscrew the two Securing Screws and carefully remove the Backplate from
the Shower Control.
9.
Fit the ‘O’ Key over the Green Temperature Hub and onto the Brass Nut.
10.
Turn the ‘O’ Key anticlockwise to unscrew the Cartridge from the Body and pull
the Cartridge clear.
Locking Ring
Lever Retainer
Flow Lever Adapter
Flow Lever
Grey Control Bearing
Temperature Knob
‘O’ Key
Important!
Do not remove for Built-in Model