background image

15

Installation of the RAC Assembly

1.

  Before the RAC assembly can be fitted you 

must have first installed your built-in shower 

control and have connected the inlet and outlet 

pipework.

 

Important! 

Make sure that the outlet pipework 

protrudes through a Ø25 mm hole in the wall 

or stud partition by at least 40 mm.

 

Note!

 For stud partition installations where 

access to the rear of the partition is possible, 

fit the RAC wall plate over the outlet pipework 

on the inside of the partition.

  For stud partition installations where access 

to the rear of the wall is not possible, follow 

instructions for solid wall installations, making 

sure that suitable wall fixings (not supplied) are 

used to secure the wall plate to the outside of 

the stud partition.

40 mm

RAC Wall Plate

(shown fitted for rear 

access stud partitions only)

Outlet Pipe to Fittings

Mixing Valve

2.

  Temporarily cap off the outlet pipe, turn on the 

water supplies and check for leaks.

3. 

Determine the finished wall position e.g. tile 

thickness. Turn off the water supply, carefully 

uncap the outlet pipe and cut to length, the 

outlet pipe must protrude through the 

finished 

wall surface

 by 21–23 mm.

 

Note!

 Remove any burrs from the pipes before 

proceeding.

4. 

For solid wall installations or stud partition 

installations 

without

 rear access go to build 

instruction 9.

  For stud partition installations with access to 

the rear of the partition continue with build 

instruction 5.

5.

  Finish the wall, e.g. tiles.

6. 

Place the RAC backplate over the outlet pipe 

with the arrow pointing up. The screw holes 

should be at 45° to the horizontal.

7. 

Mark the positions of the two RAC backplate 

fixing holes and drill two Ø5.5 mm holes.

 

Caution! 

Make sure that you do not drill into 

pipework in the wall.

8. 

Hold the RAC wall plate in position on the 

rear of the partition, insert the two backplate 

screws and secure the RAC backplate to the 

wall plate. Make sure that the foam seal abuts 

the finished wall surface. Go to instruction build 

18.

9.

  Loosely attach the RAC backplate to the RAC 

wall plate, using the two backplate screws 

provided.

10.

 Place the RAC backplate/wall plate assembly 

over the outlet pipe with the arrow pointing 

vertically up. The screw holes should be at 

40° to the horizontal.

11.

 Mark the positions of the two RAC wall plate 

fixing holes.

12. 

Remove the assembly from the wall and 

separate the backplate from the wall plate.

RAC Backplate

Backplate 

Screws

Wall Plate

RAC Backplate

Backplate Screws

Arrow

40°

Summary of Contents for Element SLT

Page 1: ...1 MIRA ELEMENT SLT INSTALLATION AND USER GUIDE THERMOSTATIC MIXER These instructions must be left with the user...

Page 2: ...ngle lever for on off and temperature control A Mid Flow Overide feature allows up to 30 reduction in flow at low pressures and a Temperature Overide warns when moving into a hotter temperature zone A...

Page 3: ...commissioned operatedand maintained in accordance with manufacturer s recommendations 2 Type 2 Valves are only used for applications covered by their approved designations refer to section Type 2 Valv...

Page 4: ...1 x 2 5 mm Hexagonal Key q 1 x 2 5 mm Hexagonal Key q 1 x Multi Tool q 1 x Multi Tool q 1 x 14 L Min Flow Regulator q 1 x 14 L Min Flow Regulator q 2 x Securing Brackets q 4 x Bracket Securing Screws...

Page 5: ...could detrimentally affect thermostatic performance For safety and performance reasons it is recommended that the maximum hot water temperature is limited to 65 C Cold Water Range up to 25 C Minimum...

Page 6: ...6 All dimensions in mm Built in Thermostatic Mixer 153 56 116 142 35 62 183 108 30 59 80 Building in Depth 45 56 Exposed Thermostatic Mixer Dimensions...

Page 7: ...y Regulations 1999 Water Fittings or any particular regulations and practices specified by the local water company or water undertakers Note Make sure that all site requirements correspond to the info...

Page 8: ...r solid walls drill the holes for the backplate with a 6 mm diameter drill and insert the wall plugs Note For other types of wall structure alternative fixings may be required not supplied Wall Plug 4...

Page 9: ...the backplate to the wall using the screws 8 For Rear Entry Supplies Only Fit the concealing plates over the inlet pipes Note Apply silicone sealant to the back face of the flange Apply Silicone Seal...

Page 10: ...upplied Remove the elbows and install on opposite sides Retighten the grubscrews Caution Do not overtighten Note Make sure that the O seals are correctly fitted and that the filter caps can be accesse...

Page 11: ...mponents will not fit correctly then mark the positions of the fixing screw holes on the wall 7 For solid walls drill two 6 mm holes for the wall plugs 8 Fit the hot and cold supply pipes Hot Left Col...

Page 12: ...r Plugs are positioned so that they can be removed for servicing 5 Drill the two 5 5 mm holes for the fixing positions countersink the holes at the front 6 Fit the hot and cold supply pipes Hot Left C...

Page 13: ...6 mm holes for the wall plugs Caution Do not drill into pipes in the wall 6 Fit the hot and cold supply pipework Hot Left Cold Right 7 Caution It is essential at this point that the supply pipework is...

Page 14: ...rill four 6 mm holes for the wall plugs For other types of wall structure alternative fixings may be required not supplied 17 Insert the wall plugs and attach the concealing ring to the wall with the...

Page 15: ...wall surface by 21 23 mm Note Remove any burrs from the pipes before proceeding 4 For solid wall installations or stud partition installations without rear access go to build instruction 9 For stud pa...

Page 16: ...1 This completes the installation of the RAC assembly Dome Shroud Chrome Trim Built in models only Dome Clamp Bearing Bracket Securing Screw REVERSED INLET SUPPLIES The Mira Element SLT thermostatic m...

Page 17: ...nsert was originally removed from pushing the hinge pin in from right to left 13 Make sure that the two cartridge inlet seals are fitted and carefully push the cartridge into the body aligning the car...

Page 18: ...dge and engage with the temperature adjusting screw 4 Rotate the hexagon key until the required maximum temperature is obtained at the shower Turn anticlockwise to increase the temperature or clockwis...

Page 19: ...tap The maximum temperature takes account of the allowable temperature tolerances inherent in thermostatic mixing valves and temperature losses in metal baths It is not a safe bathing temperature for...

Page 20: ...ter that is to be tested Any TMV that has been adjusted or serviced must be re commissioned and re tested in accordance with the instructions given in this guide The installation of thermostatic mixin...

Page 21: ...ted or plastic fittings Do not use descalents on this product Inlet Filters The inlet filters should be checked and cleaned as necessary every 12 months Note The inlet filters must not be removed exce...

Page 22: ...mm hexagonal wrench and remove the filters Note Use pliers to carefully remove the filters 6 Clean each of the filters under a jet of water to remove any lodged particles 7 Refit the filters and tight...

Page 23: ...nnector Pack 1663 265 Flow Regulator Pack 1656 114 Elbow Connector Pack 1656 112 Elbow Assembly 1656 111 Elbow Cap 1062477 Filter Pack x2 1656 113 Backplate 1656 117 Inlet Connector Pack 1656 110 Seal...

Page 24: ...B 1595 066 Filter Pack x2 1595 046 Seal Pack Identified A 1656 168 Screw Pack Identified B 1595 150 Elbow Assembly Both sides A 1656 167 Trim Pack 1656 161 Overide Pack A 1656 160 Cartridge Assembly...

Page 25: ...25 RAC Assembly 1617 171 RAC Shroud 450 20 RAC Mounting Pack 450 20 RAC Mounting Pack 1663 265 Flow Regulator Pack...

Page 26: ...DCV H Chrome 1 0 110 55 1 DCV H An outlet double check valve designed to prevent the backflow or backsiphonage of potentially contaminated water through shower controls which are fitted with a flexib...

Page 27: ...27 NOTES...

Page 28: ...d If you require further assistance call our Customer Services Team Extended Guarantees A selection of protection plans are available that enable you to cover repair bills for the life of your policy...

Reviews: