General

This Product is precision engineered and should 

give continued safe and controlled performance, 

provided:

1.

  It is installed, commissioned, operated and 

maintained in accordance with manufacturers 

recommendations.

2.

  Periodic attention is given, when necessary, 

to maintain the product in good functional 

order.

The Mira Element SLT thermostatic mixer is 

designed to need only minimal maintenance in 

normal use. The only serviceable parts are the 

inlet filters which should be checked and cleaned 

every 12 months. If a malfunction occurs with the 

thermostatic cartridge then this will necessitate a 

complete cartridge replacement.

Note!

 The cartridge contains no internally 

serviceable parts.
If you require a Mira trained engineer or agent, 

refer to section: 

‘Customer Service’

.

Lubricants

Silicone based lubricants must only be used on 

the rubber seals. 

Caution!

 Oil based or other lubricant types may 

cause rapid deterioration of seals.

Cleaning

The chrome plated parts should be cleaned using 

a mild washing up detergent or soap solution, 

rinsed and then wiped dry with a soft cloth.

Warning!

 Many household cleaners contain 

abrasive and chemical substances, and should not 

be used for cleaning plated or plastic fittings. 

Do not 

use descalents on this product.

Inlet Filters

The inlet filters should be checked and cleaned 

as necessary every 12 months.

Note!

 The inlet filters must not be removed except 

for cleaning. If the thermostatic mixer is operated 

without the inlet filters fitted the warranty on the 

product will be void.

Exposed Models
1.

  Isolate the hot and cold water supplies and 

operate the control lever to drain any residual 

water.

2.

  Using  the  multi  tool  (supplied)  to  assist, 

carefully remove the filter blanking caps then 

unscrew the filter caps with the multi tool or 

a 12 mm hexagonal wrench. Remove the 

filters.

Filter Blanking Cap

Filter Cap

Filter

3.

  Clean the filters under a jet of water to remove 

any lodged particles.

4.

  Refit the filters and tighten the filter caps.

 

Note!

  Make  sure  that  the  ‘O’  seal  is  fitted 

correctly and not damaged.

5.

  Turn on the hot and cold water supplies and 

check for leaks.

6.

  Refit the filter blanking caps.

Built-in Models
Note! 

Refer to illustrations in section: 

‘Control 

Assembly (Built-in Models)’

.

1.

  Isolate the hot and cold water supplies and 

operate the control lever to drain any residual 

water.

2.

  Use the slotted end of the multi tool (supplied)  

or a suitably sized screwdriver inserted into 

the recess to prise the control lever trim away 

from the control lever.

3.

  Use a 2.5 mm hexagonal key to remove the  

control lever securing screw then remove the 

control lever.

Summary of Contents for Element SLT

Page 1: ...1 MIRA ELEMENT SLT INSTALLATION AND USER GUIDE THERMOSTATIC MIXER These instructions must be left with the user...

Page 2: ...ngle lever for on off and temperature control A Mid Flow Overide feature allows up to 30 reduction in flow at low pressures and a Temperature Overide warns when moving into a hotter temperature zone A...

Page 3: ...commissioned operatedand maintained in accordance with manufacturer s recommendations 2 Type 2 Valves are only used for applications covered by their approved designations refer to section Type 2 Valv...

Page 4: ...1 x 2 5 mm Hexagonal Key q 1 x 2 5 mm Hexagonal Key q 1 x Multi Tool q 1 x Multi Tool q 1 x 14 L Min Flow Regulator q 1 x 14 L Min Flow Regulator q 2 x Securing Brackets q 4 x Bracket Securing Screws...

Page 5: ...could detrimentally affect thermostatic performance For safety and performance reasons it is recommended that the maximum hot water temperature is limited to 65 C Cold Water Range up to 25 C Minimum...

Page 6: ...6 All dimensions in mm Built in Thermostatic Mixer 153 56 116 142 35 62 183 108 30 59 80 Building in Depth 45 56 Exposed Thermostatic Mixer Dimensions...

Page 7: ...y Regulations 1999 Water Fittings or any particular regulations and practices specified by the local water company or water undertakers Note Make sure that all site requirements correspond to the info...

Page 8: ...r solid walls drill the holes for the backplate with a 6 mm diameter drill and insert the wall plugs Note For other types of wall structure alternative fixings may be required not supplied Wall Plug 4...

Page 9: ...the backplate to the wall using the screws 8 For Rear Entry Supplies Only Fit the concealing plates over the inlet pipes Note Apply silicone sealant to the back face of the flange Apply Silicone Seal...

Page 10: ...upplied Remove the elbows and install on opposite sides Retighten the grubscrews Caution Do not overtighten Note Make sure that the O seals are correctly fitted and that the filter caps can be accesse...

Page 11: ...mponents will not fit correctly then mark the positions of the fixing screw holes on the wall 7 For solid walls drill two 6 mm holes for the wall plugs 8 Fit the hot and cold supply pipes Hot Left Col...

Page 12: ...r Plugs are positioned so that they can be removed for servicing 5 Drill the two 5 5 mm holes for the fixing positions countersink the holes at the front 6 Fit the hot and cold supply pipes Hot Left C...

Page 13: ...6 mm holes for the wall plugs Caution Do not drill into pipes in the wall 6 Fit the hot and cold supply pipework Hot Left Cold Right 7 Caution It is essential at this point that the supply pipework is...

Page 14: ...rill four 6 mm holes for the wall plugs For other types of wall structure alternative fixings may be required not supplied 17 Insert the wall plugs and attach the concealing ring to the wall with the...

Page 15: ...wall surface by 21 23 mm Note Remove any burrs from the pipes before proceeding 4 For solid wall installations or stud partition installations without rear access go to build instruction 9 For stud pa...

Page 16: ...1 This completes the installation of the RAC assembly Dome Shroud Chrome Trim Built in models only Dome Clamp Bearing Bracket Securing Screw REVERSED INLET SUPPLIES The Mira Element SLT thermostatic m...

Page 17: ...nsert was originally removed from pushing the hinge pin in from right to left 13 Make sure that the two cartridge inlet seals are fitted and carefully push the cartridge into the body aligning the car...

Page 18: ...dge and engage with the temperature adjusting screw 4 Rotate the hexagon key until the required maximum temperature is obtained at the shower Turn anticlockwise to increase the temperature or clockwis...

Page 19: ...tap The maximum temperature takes account of the allowable temperature tolerances inherent in thermostatic mixing valves and temperature losses in metal baths It is not a safe bathing temperature for...

Page 20: ...ter that is to be tested Any TMV that has been adjusted or serviced must be re commissioned and re tested in accordance with the instructions given in this guide The installation of thermostatic mixin...

Page 21: ...ted or plastic fittings Do not use descalents on this product Inlet Filters The inlet filters should be checked and cleaned as necessary every 12 months Note The inlet filters must not be removed exce...

Page 22: ...mm hexagonal wrench and remove the filters Note Use pliers to carefully remove the filters 6 Clean each of the filters under a jet of water to remove any lodged particles 7 Refit the filters and tight...

Page 23: ...nnector Pack 1663 265 Flow Regulator Pack 1656 114 Elbow Connector Pack 1656 112 Elbow Assembly 1656 111 Elbow Cap 1062477 Filter Pack x2 1656 113 Backplate 1656 117 Inlet Connector Pack 1656 110 Seal...

Page 24: ...B 1595 066 Filter Pack x2 1595 046 Seal Pack Identified A 1656 168 Screw Pack Identified B 1595 150 Elbow Assembly Both sides A 1656 167 Trim Pack 1656 161 Overide Pack A 1656 160 Cartridge Assembly...

Page 25: ...25 RAC Assembly 1617 171 RAC Shroud 450 20 RAC Mounting Pack 450 20 RAC Mounting Pack 1663 265 Flow Regulator Pack...

Page 26: ...DCV H Chrome 1 0 110 55 1 DCV H An outlet double check valve designed to prevent the backflow or backsiphonage of potentially contaminated water through shower controls which are fitted with a flexib...

Page 27: ...27 NOTES...

Page 28: ...d If you require further assistance call our Customer Services Team Extended Guarantees A selection of protection plans are available that enable you to cover repair bills for the life of your policy...

Reviews: