Plumbing Schematic Diagram
(to be used with pipework table overleaf)
1.16.
Avoid layouts where the hose will be sharply kinked. This may reduce the life of
the hose.
1.17.
Long pipe runs and excessive use of 90° elbows will significantly reduce the
available head to supply the Elite 2. The pipework table should be completed to
ensure that adequate head is available for any given application.
Spill-over
Level
25 mm Minimum
Hose Retaining
Ring
1.15.
When installed in very hard water
areas (above 200 ppm temporary
hardness) your installer may advise
the installation of a water treatment
device, to reduce the effects of
limescale formation. Mira Elite 2
malfunction due to excessive
limescale formation is not covered
by the manufacturer’s guarantee.
Your local water company will be
able to advise the hardness of water
in your area.