22
FAULT DIAGNOSIS
The trouble shooting information table below gives details on probable causes and
remedies should difficulties be encountered whilst the shower is in operation.
Warning!
There are no user serviceable components beneath the cover of the
appliance.
Only a competent tradesperson should remove the front cover!
Symptom
Power
Light
Heater
Setting
Low/
Med/
High
Probable Cause
Possible Remedy
Shower is too
hot during the
summer.
ON
High
I n c o m i n g w a t e r i s
warmer in the summer,
so the shower heater
setting is too high.
Turn heater control to
medium and adjust
temperature control until
the desired temperature
is achieved.
Shower is too
hot.
ON
Med/
High
Handset blocked.
Remove and clean.
T u r n i n g t h e
t e m p e r a t u r e
control does not
affect the water
temperature.
ON
Med/
High
Handset blocked.
Remove and clean. If
fault persists, contact
the shower installer.
Water continues to
flow when double
pole switch is
turned off.
OFF
Any
T h e d i a p h r a g m i s
damaged.
Contact shower installer
to replace the flow valve
assembly.
No water or very
low flow rate.
OFF
ON
ON
OFF
Any
Any
Any
Any
The power is off at the
double pole switch.
The incoming water
supply stop valves, or
the appliance isolating
valve, is closed.
Handset blocked.
The fuse is blown or the
MCB/RCD has been
tripped, indicating a
possible electrical fault.
Switch on the power at
the double pole switch.
Open the stop/isolating
valve fully.
Remove and clean. For
sprayplate cleaning,
refer to the handset
manual.
Renew the fuse or reset
the MCB/RCD. If the
fault persists, contact
the shower installer.