Electrical Requirements and Information
ALL CONNECTIONS MUST BE GFCI
(Ground Fault Circuit Interrupted)
PROTECTED
1. Whirlpool and Total Massage units require dedicated 20 Amp,
120V service.
2. You must provide a receptacle with a 20-amp configuration.
3. See local codes for proper wire size. If not specified, use #12 Copper only wire.
4. Optional In-Line Heater requires its own dedicated 20 amp service.
The unit must be connected to a circuit interrupter (GFCI) provided by the installer. The (GFCI) breaker should be
tested on a routine basis.
To test the (GFCI) breaker, push the test button. The GFCI should interrupt power. To restore power, push the RESET
button. If the GFCI fails to operate in this manner there is ground current flowing, indicating the possibility of an
electrical shock. Do not use the unit. Disconnect the unit and have the problem corrected by a qualified service
representative before using.
DANGER
DANGER
RISK OF ELECTRICAL SHOCK.
All pumps and blowers must be connected
to a ground fault circuit interrupter (GFCI) protected outlets. Standard Line
Total Massage units can be operated on a single service. All heaters must be
connected to a ground fault circuit interrupter (GFCI) protected outlets, separate
from the pump and/or blower.
Electrical outlet must be mounted 4” (101mm) above the floor line and 12’’
max (305mm) inside from the edge of the bathtub, or in accordance with local
building and electrical codes.
• Risks of component over heat. Do not use electric extension cord to power
the unit. Operating the pump without enough water in bathtub can cause
permanent damage to the pump/motor.
• If CFGI unit indicates a malfunction, per manufacturer’s instructions, turn OFF
power and do not attempt to use the bathtub until the source of the problem
has been identified and corrected.