Technical Data
Overall Height
:
86.6'' approx.
Overall Weight
:
82.6lbs
Overall Width
:
34''
Heater Heat Input(
∑
Qn):
38,200 Btu/h
Heater Gas Consumption
:
2.0 Lbs per hour
Heater Injector Size
:
0.07”
Setting Pressure
:
11” per W.C
Regulator Outlet Pressure
:
11” per W.C
Standard
ANSI Z83.26a-2008 • CSA 2.37a-2008
Gas Fired Outdoor infrared Patio heaters
Gas Supply Pressure
Max.250 PSI, MIN.5 PSI
Specifications are subject to change without prior notice.
Universal Innovations,
Kilcoole Ind. Est.,
Kilcoole,
Co. Wicklow,
Ireland.
Warranty
Keep these instructions for future reference.The patio heater has been manufactured under the highest standards of
quality and workmanship. We warrant to the original consumer purchaser that all aspects of this product will be free of
defects in material and workmanship for 1 year from the date of purchase. A replacement for any defective part will be
supplied free of charge for installation by the consumer. Defects or damage caused by the use of other genuine parts
are not covered by this warranty. This warranty shall be effective from the date of purchase as shown in the
purchaser’s receipt.
This warranty is valid for the original customer only and excludes product damage due to shipment or failure which
results from alteration, product abuse or product misuse whether performed by a contractor, service company, or
consumer. We will not be responsible for labor charges and/or damage incurred in installation, repair or replacement,
nor for incidental or consequential damage.
Contact:
info@uig.biz
Tel:
(678) 534 2876
Shall be used only in a well ventilated space
and shall not be used in a building, garage or
any other enclosed area. Maybe installed in
shelter no more inclusive than:
–With walls on all sides but with no overhead
cover.
– Within a partial enclosure which includes an
overhead cover and no more than two side
walls. These side walls may be parallel, as in a
breezeway, or at right angles to each other.
– Within a partial enclosure which includes an
overhead cover and three side walls, as long
as 30% or more of the horizontal periphery of
the enclosure is permanently open.
Page 17
CAUTION
• It is normal for the heater to smoke during the first few minutes of use.
• Regularly clean your patio heater after every use.
• If you smell gas – turn off the appliance and extinguish all flames. If the odour continues, immediately
contact your gas supplier.
• In the event of an uncontrollable fire, immediately disconnect the gas cylinder moving it away from fire
and contact
the fire services. DO NOT PUT YOURSELF AT RISK!
• Ensure aerosols are not used near this unit when in use.
• Ensure all packaging and plastic bags are disposed of safely.
40”(1M)