background image

 

 

 

 

 
 
 
 
 
 

 

DENSITÉ 

series

 

 
 
 
 
 
 
 
 

 

HDA-1861 

 

Reclocked HD/SD/ASI DA with EQ 

 

Guide to Installation and Operation 

 

 

M950-9900-100 

 

 

15 Mar 2011 

 

 
 
 
 
 
 
 
 
 
 
 
 

 

 

Miranda 

 

Technologies Inc. 

 

3499 Douglas-B.-Floreani 

 

St-Laurent, Québec, Canada H4S 2C6

 

 

 

Tel. 514-333-1772 

 

Fax. 514-333-9828 

 

www.miranda.com 

 
 
 

© 2011  Miranda Technologies Inc.

Summary of Contents for Densite HDA-1861

Page 1: ...D ASI DA with EQ Guide to Installation and Operation M950 9900 100 15 Mar 2011 Miranda Technologies Inc 3499 Douglas B Floreani St Laurent Québec Canada H4S 2C6 Tel 514 333 1772 Fax 514 333 9828 www miranda com 2011 Miranda Technologies Inc ...

Page 2: ...nterference at his own expense This equipment has been tested and found to comply with the requirements of the EMC directive 2004 108 CE EN 55022 Class A radiated and conducted emissions EN 50204 Radiated EMF immunity 900 MHz pulsed EN 61000 3 3 Limitation of voltage changes voltage fluctuations and flicker EN 61000 4 2 Electrostatic discharge immunity EN 61000 4 3 Radiated electromagnetic field i...

Page 3: ...rface 6 2 Installation 7 2 1 Installation of Rear Connector Panels 7 2 2 Card Installation 8 2 3 Installing Densité 2 Cards and Rear Modules in a Densité 3 Frame 8 2 4 Signal Connections on Rear Connector Panels 10 3 Operation 11 3 1 Card Edge Status LED 11 3 2 Local control using the Densité frame control panel 11 3 2 1 Overview 11 3 2 2 Menu for local control 12 4 Specifications 14 ...

Page 4: ...GUIDE TO INSTALLATION AND OPERATION HDA 1861 ...

Page 5: ...861 DA supports both HD SDI SMPTE 292M and SD SDI SMPTE 259M C and also offers signal presence detection and remote reporting 1 2 Features HD SD SDI input 9 reclocked HD SD SDI outputs HD SDI 1 485 1 485 1 001 Gbps is reclocked SD SDI 270 Mbps is reclocked Other SD signals 143 177 360 540 are equalized but not reclocked 140 m automatic cable equalization in HD 300 m automatic cable equalization in...

Page 6: ...HDA 1861 1 4 Front Card edge Interface The front card edge of the HDA 1861 incorporates two elements Status LED see section 3 1 Select Button see section 3 2 Figure 1 2 Front card edge layout Select Status HDA 1861 Status LED Select Button ...

Page 7: ...lable adapters HDA 185N 186N SRP DENSITE SRP 3RU 1 input and 4 outputs HDA 185N 186N DRP DENSITE DRP 3RU 1 input and 9 outputs All cards and rear panels can be installed with the frame power on The card has connectors which plug into a mid frame mother board for distribution of power and for connection to the controller card and a second connector which plugs directly into the rear connector panel...

Page 8: ...té 2 Cards and Rear Modules in a Densité 3 Frame The Densité 3 frame supports many Miranda Densité 2 series cards including the HDA 1861 Should you wish to install the HDA 1861 card in your Densité 3 frame you will need an adapter for the card You may use the 3 RU rear panel that is available for the HDA 1861 HDA 185N 186N 3SRP or you may use one of the two 2 RU rear panels In the latter case an a...

Page 9: ...P 3RU o DENSITE SRP 3RU Install these as follows 1 Position the adapter at the top of the empty slot s on the rear of the frame 2 Use the captive screw in the adapter to fasten it securely in position 3 Slip the top of the 2RU rear panel into the slot at the bottom of the adapter and secure it to the frame using the captive screw at the bottom of the panel ...

Page 10: ...ngle slot width Densité 2 panel Connections 1 x HD SDI IN 4 x HD SDI OUT HDA 185N 186N SRP double slot width Densité 2 panel Connections 1 x HD SDI IN 9 x HD SDI OUT HDA 185N 186N 3SRP single slot width Densité 3 panel Connections 1 x HD SDI IN 7 x HD SDI OUT Note On all of these panels the outputs identified with a black label are not suitable for ASI distribution ...

Page 11: ...selected for local control using the Densité frame s control panel or that the card is booting up See Section 3 2 for details 3 2 Local control using the Densité frame control panel 3 2 1 Overview Push the SELECT button on the HDA 1861 card edge see Section 1 4 to assign the local control panel to operate the HDA 1861 Use the control panel buttons to navigate through the menu as described below Al...

Page 12: ... normal standby status and the selected card s STATUS LED reverts to its normal operating mode If a parameter was changed on the card but not submitted SELECT was not pressed and the 30 second timeout occurs the parameters will be confirmed as if the SELECT key had been pressed 3 2 2 Menu for local control The HDA 1861 has operating parameters which may be adjusted locally at the controller card i...

Page 13: ...ch it will be displayed on the card edge Status LED Alarm level GREEN YELLOW RED FLASH RED For each alarm select whether it will be reported on the GPI output of the frame controller Alarm report NONE GPI FACTORY DEFAULT restores the HDA 1861 to the factory set up conditions shown underlined in the menu ...

Page 14: ...th HD 140 m Belden 1694A SD 300 m Belden 1694A Return loss 15 dB up to 1 5 GHz OUTPUTS 9 Signal HD SDI SMPTE 292M 1 485 1 485 1 001 Gbps SD SDI SMPTE 259M C 270 Mbps EN50 83 9 DVI ASI 270 Mbps 5 outputs only Other SD signals 143 177 360 540 are equalized but not reclocked Return loss 15 dB up to 1 5 GHz Jitter wideband 0 2 UI p p wideband PROCESSING PERFORMANCE Signal path 10 bits Latency 6 ns POW...

Reviews: