Backup:
use this pulldown list to select the source that will be used if the primary source
becomes unavailable or invalid. In addition to the available primary sources, the list includes:
•
Last valid – return to the last valid source used
•
Blank – no metadata output
•
Generator – use the internal generator
Generator:
Use this pulldown list to turn the internal generator ON or OFF. Turning it ON selects it as the source. The
generator creates a complete, specific set of metadata, which is configured in the Generator tab.
Generator automated mode
:
The generator is turned on or off automatically in specific conditions to avoid loss of metadata at the output stream.
There are two specific conditions which will trigger the automation behaviors:
1. When a Dolby decoder module is installed and selected as the metadata source of a path, the audio
metadata from a Dolby E input stream will be decoded and passed. When the decoder is fed with PCM audio,
the Dolby decoder will not provide metadata. Instead, the generator will be automatically turned on. It is the
responsibility of the user to configure the generator with the proper PCM metadata parameters.
2. When an upMAX
tm
module is installed and configured to operate in
Follow Metadata
mode, the resulting
upMAX
tm
mode is dictated by the
coding mode
parameter of the probed metadata stream. When the
metadata stream coding mode is 2/0, the upMAX
tm
mode is set to
Upmix
and the generator will be turned on
to generate 5.1 metadata for the upmixed audio content. It is the responsibility of the user to configure the
generator with the proper 5.1 metadata parameters. If the metadata stream coding mode is 3/2, the upMAX
tm
mode is set to
Pass
and the generator will be turned off to let the input metadata stream go through. If the
coding mode detected is other than 2/0 or 3/2 or there is no metadata, the reversion mode is used. In that
case, the generator will be turned on for the
Upmix
and
AutoMAX
reversion modes, and off for
Pass
reversion
mode.
Note:
No automation is provided for the generator content. The generator content is always under user
control and must have been previously configured if used in these conditions.
Hold:
Use the pulldown to select Hold ON or OFF.
•
ON – freezes the Metadata values used in the output bitstream
•
OFF - allows the current metadata to pass to the output
Probe:
this box shows where the audio metadata probing occurs in the path.
5.9.1.1 [Config]
→
[Delay]
Through
Coarse
and
Fine
adjustments, a fixed delay can be
applied to the Metadata bitstream. It is useful when
processing, like watermarking, is applied to the audio signal
outside the FRS-3901. The delayed Metadata bitstream will
stay properly timed with its associated audio signal.
Figure 5-24 Dolby Metadata - [Config]
→
[Delay]