[Config]
→
[Generator]
→
[Extended BSI]
•
Preferred Stereo Downmix
•
Lt/Rt Center Mix Level
•
Lt/Rt Surround Mix Level
•
LoRo Center Mix Level
•
LoRo surround Mix Level
•
Surround EX mode
•
Converter Type
5.9.1.4 [Config]
→
[Presets]
Because there are many parameters to set for the
generator, it is convenient to be able to save a
configuration for easy recall. The Presets tab offers
several convenient functions for this purpose.
The FRS-3901 allows the user to save five
configurations. These are labeled META 1 to META
5 by default, but the user can edit the names via the
Edit Presets Labels…
button at the bottom of the
tab.
In addition, the FRS-3901 is preloaded with two fixed
data sets named Factory 2.0 and Factory 5.1.
The Current Generator Preset databox at the top of
the tab reports the current preset in use.
•
If all parameter values do not match the preset
values, the box will show “Custom”.
The
Generator Presets
pulldown gives access to all
seven available presets. The two buttons to the right then allow two options:
•
Load – load the generator with the values stored in the preset, overwriting the current settings
•
Save – overwrite the values stored in the preset with the values currently set on the card (only for the five user-
settable presets – the Factory presets cannot be changed).
Figure 5-32 [Config]
→
[Generator]
→
[Extended BSI]
Figure 5-33 [Config]
→
[Presets]