Segment Marker
Select the checkboxes corresponding to the events for which you want a segment marker inserted in the loudness log
file:
•
User Event – a manually-triggered RESET (but not a PAUSE).
•
GPI – a RESET triggered externally via GPI input.
•
Dialnorm change – a change in Dialnorm value in the incoming metadata stream.
•
Coding Mode Change – a change in the coding mode, either through the manual settings or detected in the
incoming metadata stream.
Note that segment marker triggers in one PGM will generate segment markers in the logs for all PGMs.
5.11.2 Loudness | PGM panel
Four PGM panels – PGM 1, PGM 2, PGM 3 and PGM 4 – are
available, each activated by selecting the appropriate
checkbox in the LOUDNESS-CONFIG panel.
Use these panels to define the programs whose loudness will
be monitored by this FRS-3901.
Program Settings
Operation Mode: Use the pulldown to select to source of the
program definition:
Manual:
Use the Manual Coding controls to define the
program channel
Path:
Use the path defined in the Dolby Metadata panel
(see section 5.8.1 on page 34).
Manual program definition:
Select Manual in the Operation Mode pulldown.
Select the coding mode (e.g. 2/0, 3/2L, etc.) from the Manual
Coding Mode pulldown
Assign inputs to the program channels using the Input Channels pulldowns
•
For each program channel, input CH 1 to CH 32 can be selected
•
Each input can only be selected once in a program.
•
Only the program channels corresponding to the selected coding mode will be enabled
Figure 5.39 Loudness panel – PGM 1 tab