GUIDE TO INSTALLATION AND OPERATION
62
| FRS-3901
5.18 Alarm Config panel
This panel allows the alarm reporting of the FRS-3901 to be configured. The panel opens in a new window when the
button is clicked, and can be resized if needed.
The panel is organized in columns.
Status/Name
This contains an expandable tree listing all the
alarms reported by this FRS-3901 card.
•
Each alarm name includes an icon that
shows its current status
•
Some alarms may be text-only and the
alarm status is shown in the name and not
by a status icon
The
Card LED
,
Overall alarm
and
GSM
contribution
columns contain pulldown lists that
allow the level of contribution of each individual
alarm to the alarm named in the column heading
to be set.
Click on the alarm icon to
see the available levels;
then click on one to select it
Card LED
This column allows configuration of the
contribution of selected individual alarms to the
status LED located on the front card edge. The
Card LED status is shown at the bottom of the
alarm tree in the Status/Name column.
Overall Alarm
This column allows configuration of the
contribution of each individual alarm to the
Overall Alarm associated with this card. The
Overall Alarm is shown in the upper left corner of
the iControl panel, and also appears at the
bottom of the Status/Name column.
GSM Contribution
This column allows configuration of the contribution of each individual alarm to the GSM Alarm Status associated with
this card. GSM is a dynamic register of all iControl system alarms, and is also an alarm provider for external
applications. The possible values for this contribution are related to the Overall alarm contribution:
•
If the Overall alarm contribution is selected as Disabled, the GSM alarm contribution can be set to any available
value
•
If the Overall alarm contribution is selected as any level other than disabled, the GSM contribution is forced to
follow the Overall Alarm.
Figure 5-60 Alarm Configuration panel