background image

HDA-1832 HD/SD Reclocked Digital Video DA 

Guide to Installation and Operation 

 

 

HDA-1832 

Page 3 of 4 

The HDA-1832 is also equipped with the remote 
reporting and control capabilities of the DENSITÉ 
series. Fault reporting is carried out on a frame-wide 
basis. There is no individual rear-panel access to the 
fault and status reporting port of the HDA-1832. 
Interfacing to the outside world is handled by the 
frame’s contoller card. The fault reporting protocol is 
standardized across the DENSITÉ series of modules. 
 

Status Monitor LED 

 
The status monitor LED is located on the front card-
edge of the HDA-1832 module, and is visible through 
the front access door of the DENSITÉ frame. 
 
This multi-color LED indicates module status by 
color, and by flashing/steady illumination, according 
to the following chart. The chart also indicates fault 
reporting for this card on the DENSITÉ frame’s serial 
and GPI interfaces. 
 

Status Indicator  

 

REPORT 

COLOR (F=flashing) 

 

SERIAL 

GPI 

FR 

No errors 

 

 

µ

 

 

 

 

No Input 
Signal 

µ

 

 

 

 

µ

 

 

No rear 
panel 

 

 

 

 

 

µ

 

No lock 
on input 

µ

 

 

 

 

µ

 

 

µ

 : Factory default. 

 
NOTE: A “Flashing Yellow” Status LED indicates that 
the SELECT button on the front panel has been 
pushed, and the card is being accessed by the 
controller. The LED color assignments for the various 
error conditions can be reconfigured by the user. 
 

User Interface  

 
Push the SELECT button on the front edge of the 
HDA-1832 to see a report of the current error status 
on the DENSITÉ frame’s controller card display. The 
HDA-1832 has three possible status messages: 
 

 

STATUS 

 

SIGNAL UNKNOWN – NO LOCK - NO SIGNAL - 143 
Mb/s – 270 Mb/s – 360 Mb/s – 540 Mb/s – 1.48 Gb/s 

 

 

 

 

NO REAR - SINGLE REAR - DOUBLE REAR 

 
 

 

 

VERSION XXX 

 

The STATUS LED will revert to it’s normal state upon 
a second push of the button, or after a short delay 
otherwise. 

 

 

Example : 

SELECT button pushed when the status LED is 
green: 

 

 

 
 
 

 

SELECT button pushed when there is no input 
signal connected to the rear panel and the LED 
is steady red: 
 
 

 
 

 

The HDA-1832 has operating parameters which may 
be adjusted using menus operated at the controller 
card interface. After pressing the SELECT button on 
the HDA-1832 card, use the keys on the local control 
panel to step through the menu and adjust these 
parameters. The menus, including the parameters 
which can be adjusted, and the options which are 
available, are shown on page 4. 
 

CONFIG ALARM

 menu: 

Allows the user to set the Status LED display for the 
NO SIGNAL and NO LOCK conditions, and to 
determine whether GPI alarms will be triggered. 
 

FACTORY DEFAULT

 restores the HDA-1832 to the 

factory set-up conditions, shown underlined in the 
menu. 
 
The use of the local control panel is described in 
more detail in the controller card manual. 

 
 
 
 
 
 
 
 

 
 
 

H D A - 1 8 3 2

O K

S T A T U S

H D A - 1 8 3 2

A L

N O

S I G N

Summary of Contents for HDA-1832

Page 1: ... This multi rate feature makes the HDA 1832 ideal for applications where HD and SD signals may coexist The HDA 1832 is designed for use in the DENSITÉ frame FEATURES HD SDI input 9 HD SDI reclocked outputs Supports HD SDI 1 48 Gbps Supports SD SDI 143 540 Mbps 110 m automatic cable equalization Signal presence detection with remote reporting SPECIFICATIONS INPUT Signal HD SDI SMPTE 292M 1 48 Gbps ...

Page 2: ...slot in order to mate with the rear panel connectors If it is placed in the wrong slot the front panel LED will flash red Move the card to other slot for correct operation No damage will result to the card should this occur Should you require four or fewer outputs you can free up a slot in the frame for another card by using the optional single width rear panel HDA 18NN SRP This panel brings outpu...

Page 3: ... conditions can be reconfigured by the user User Interface Push the SELECT button on the front edge of the HDA 1832 to see a report of the current error status on the DENSITÉ frame s controller card display The HDA 1832 has three possible status messages STATUS SIGNAL UNKNOWN NO LOCK NO SIGNAL 143 Mb s 270 Mb s 360 Mb s 540 Mb s 1 48 Gb s NO REAR SINGLE REAR DOUBLE REAR VERSION XXX The STATUS LED ...

Page 4: ... certified peripheral devices is likely to result in interference with radio and television reception This equipment has been tested and complies with the limits in accordance with the specifications in FCC Part 15 Subpart B CE EN50081 1 1992 CE EN50082 1 1992 CONTACT MIRANDA For technical assistance please contact the Miranda Technical support centre nearest you Americas Telephone 1 800 224 7882 ...