126
Configuring Alarms
6
Example of alarms related to video and embedded audio input signals
4. In the
Properties
tab, set the relevant values under
Calibration
.
Video Calibrations
Black detection threshold Set the level (in IRE or mV) below which the signal will be considered to be
black. By default the threshold is set at 8 IRE, and the alarm will be triggered
after 3 occurrences of at least 5 seconds of black within a period of 1 minute.
Luma too high detection
threshold
Set the level (in IRE or mV) above which Luma Too High will be reported.
Freeze sensitivity
Freeze detection is done by comparing successive frames. Noise in the signal
could disrupt this process, so filtering is added to remove it. Adjust the
sensitivity according to the signal being monitored, on a range of 0 (for a
noisy signal) to 16 (for a clean signal). By default the sensitivity is set at 8, and
the alarm will be triggered after 3 occurrences of a least 5 seconds of freeze
within a period of 1 minute. Once the alarm is triggered it will only be
released if no other freeze condition is detected over the specified reset delay
period (by default, there is no delay), in order to avoid unwanted alarm
flickering that could be caused by glitches on the signal.
Summary of Contents for Kaleido-X
Page 1: ...Kaleido X User s Manual Part Number M770 2800 111 1 June 2011 ...
Page 8: ...viii toc ...
Page 33: ...Loading a Layout 25 Kaleido X16 ...
Page 34: ...26 Getting Started 2 Kaleido X 4RU ...
Page 152: ...144 Creating Logical Sources 7 ...
Page 178: ...170 Setting Up Rooms 8 ...
Page 244: ...236 Creating Layouts 9 ...
Page 253: ...Detailed Directions 245 3 Under Properties General type a Friendly name for the Action ...
Page 256: ...248 Creating Actions 10 ...
Page 272: ...264 Managing Kaleido RCP2 Users 11 ...
Page 348: ...340 Tally Interface Devices 13 ...
Page 350: ......
Page 352: ...344 Using the Serial to TCP IP Dispatcher 15 ...
Page 406: ...398 Index ...