28
Getting Started
2
RS-422 Connection Diagram
In the case of a
Kaleido-X
multi-viewer, each output card supports one RS-422 port over an RJ-45
connector. The
Kaleido-X16
supports two RS-422 serial inputs over RJ-45 connectors. These inputs allow
the multi-viewer to connect to external serial devices such as a router, production switcher, or router
controller.
The pinout for the RS-422 signals on the Kaleido-X16’s RJ-45 connectors, and the wiring diagrams for the
appropriate adapters, are shown here:
Standard wiring between multi-viewer and devices wired to SMPTE “slave” specification (e.g. most routers, Ross Synergy
switchers, Nevion ETH-CON)
Standard wiring between multi-viewer and devices wired to SMPTE “master” specification (e.g. Philips Jupiter router control
system, Miranda Presmaster PCS)
Note:
For information on the
KMV-3911
multi-viewer’s RS-422 interface, refer to the
KMV-3911 Guide
to Installation and Operation
, available on the DVD that shipped with your system.
Note:
The RS-422 ports each have an RJ-45 connector in order to preserve space on a busy panel. The
RS-422 interface specifies a DE-9 connector, so if you are using this interface, you will require a
DE-9-to-RJ-45 adapter. Miranda supplies two adapter models, correctly wired for this application: a
straight adapter (part no. 1737-3000-102), and a crossover adapter (part no. 1792-3700-100).
Pinout of each RS-422 port’s
RJ-45 connector on the
multi-viewer
Pinout of
straight
adapter
(Miranda part no. 1737-3000-102)
RJ-45
DE-9 male
DE-9 female
Pinout of RS-422 connector
on SMPTE
slave
device
Pinout of each RS-422 port’s
RJ-45 connector on the
multi-viewer
RJ-45
DE-9 male
DE-9 female
Pinout of
crossover
adapter
(Miranda part no. 1792-3700-100)
Pinout of RS-422 connector
on SMPTE
master
device
Summary of Contents for Kaleido-X
Page 1: ...Kaleido X User s Manual Part Number M770 2800 111 1 June 2011 ...
Page 8: ...viii toc ...
Page 33: ...Loading a Layout 25 Kaleido X16 ...
Page 34: ...26 Getting Started 2 Kaleido X 4RU ...
Page 152: ...144 Creating Logical Sources 7 ...
Page 178: ...170 Setting Up Rooms 8 ...
Page 244: ...236 Creating Layouts 9 ...
Page 253: ...Detailed Directions 245 3 Under Properties General type a Friendly name for the Action ...
Page 256: ...248 Creating Actions 10 ...
Page 272: ...264 Managing Kaleido RCP2 Users 11 ...
Page 348: ...340 Tally Interface Devices 13 ...
Page 350: ......
Page 352: ...344 Using the Serial to TCP IP Dispatcher 15 ...
Page 406: ...398 Index ...