24
Kaleido-X16 Installation
Maintenance
1
The pinout for the RS-422 signals on the Kaleido-X16’s RJ-45 connectors, and the wiring diagram for an
appropriate adapter cable, are shown here:
Maintenance
Cleaning the Air Filter
Occasionally, the air filter has to be cleaned in order to maintain proper ventilation. The air filter is located
in the front door of the Kaleido-X16 frame. The filter may be cleaned without removing it from the door.
Note:
The Kaleido-X16’s two RS-422 ports each have an RJ-45 connector in order to preserve
space on a busy panel. The RS-422 interface specifies a DE-9S connector, so if you are using this
interface, you will require a DE-9S-to-RJ-45 adapter cable. Miranda supplies such a cable,
correctly wired for this application (Miranda part no. 1737-3000-102).
Note:
The two RS-422 ports on the Kaleido-X16 side have no ground pin. Using the
DE-9S-to-RJ-45 adapter, an external device should be able to communicate with a Kaleido-X16
despite the lack of a ground.
See also:
For more information about:
• RS-422 specifications, see “RS-422” on page 69.
• RS-422 serial connections, see “Serial Connections” in the “Routers” chapter of the Kaleido-X User’s
Manual.
Wiring diagram for an RJ-45-to-DE-9
adapter cable to connect the Kaleido-X16 to an RS-422 network
Pinout of each RS-422 port’s RJ-45
connector on the Kaleido-X16
Summary of Contents for Kaleido-X16