GUIDE TO INSTALLATION AND OPERATION
RCP-100 |
7
Case 3 (figure 3.6)
Here an iControl APPLICATION SERVER is connected to the LAN. In this case, all RCP-100s must be
configured as CLIENTs, and the APP SERVER will function as the SERVER. An RCP-100 in CLIENT mode
will control Imaging and Densité cards through the APP SERVER via the ethernet connection.
Note: Any device can be controlled by a maximum of 8 RCP-100 CLIENTs
Figure 3.6
Installation of RCP-100s with an Application Server
In this set-up, the settings would be similar to these:
•
the IP address of the AppServer is 10.2.5.10
•
the IP address of RCP-100 #1 (client) is 10.2.5.20
•
the IP address of RCP-100 #2 (client) is 10.2.5.21
Settings for RCP-100 #1 (client)
IPADDR: 10.2.5.20
SERVICE CONFIG – ICOM: OFF
DCOM:
OFF
DSRV:
OFF
DSRV IP: 10.2.5.10 (the IP address of the App. Server)
Settings for RCP-100 #2 (client)
IPADDR: 10.2.5.21
SERVICE CONFIG – ICOM: OFF
DCOM:
OFF
DSRV:
OFF
DSRV IP: 10.2.5.10 (the IP address of the App. Server)
Note: When an RCP-100 is configured as the client of an AppServer running iControl, the
iControl Services
Gateway
component must be started in the
iControl Services Monitoring and Configuration tool
. See the
iControl User’s Manual for detailed information on this setting.
The ethernet ports of the RCP-100 (client) devices must be connected to the same LAN subnet as the ETH0
port of the AppServer.