FIRE ALARM ADDRESSABLE MANUAL PULL STATIONS 

MPS-800MP(U) SERIES

Description

Mircom’s MPS-800MP(U) Series Fire Alarm Manual Pull 

Stations provide manual fire alarm activation. The new 

MPS-800 Series uses raised symbols and icons instead of 

printed text that makes them universally recognized.
These addressable pull stations are available as single or two 

stage dual action devices. Compatible with FX-400 Series and 

Flex-Net FX-4000 Fire Alarm Panels.
The MPS-800MP(U) manual stations are constructed of 

high quality polycarbonate resin thermoplastic “LEXAN” that 

supports high temperatures without deforming.
The MPS-800MP(U) addressable pull stations are accessible 

from the front for wiring while mounted making it easy to install. 

These pull stations can be mounted on a single gang backbox 

and the mounting holes permit easy alignment to the wall.
The suffix “U” indicates USA version. 
All manual fire alarm stations shall be installed as per the 

specific requirements outlined in the UL/ULC codes, as well 

as all other applicable national or local codes. 
Addressing is done using the MIX-4090 Device Programmer. 

For setting the address on this device, disconnect it from the 

loop, or ensure that the loop to which is connected is both 

disconnected from the panel and shorted across the SCL+ and 

SLC- inputs at the device. Failing to take either of these steps 

may change the address programming of previously configured 

sensors on the loop.

Features

• 

Completely made of LEXAN material

• 

Closed-fist operation (ADA – Americans with Disability Act)

• 

No printed text on the devices, symbols and icons are 

used instead

• 

Symbols are raised to be easily recognized by touch

• 

Compatible with FX-400 Series and Flex-Net FX-4000 Fire 

Alarm Panels

• 

Easy installation

• 

Accessible from the front for wiring while mounted

• 

Mounts on a single gang backbox

• 

Temperature range from 0ºC to 49ºC

• 

UL and ULC listed

• 

Device comes with a reset key

• 

Indoor use only

• 

Alarm LED is viewable from the front - Useful for trouble 

shooting

MPS-810MP(U)

1 Stage

MPS-802MP

2 Stage

Operation

Activating the Alarm

• 

Push in the push bar

• 

Pull down the pull handle

Activating the stage two alarm (MPS-802MP and
MPS-822MP)

• 

Insert the stage two key into the stage two keyhole, and 

then turn the key. 

• 

The stage two alarm activates immediately.

Resetting the manual station

• 

Insert the key into the reset keyhole and turn it.

• 

Pull the cover open. The switch is now reset.

• 

Close and lock the stations with the reset key.

• 

Reset the Fire Alarm Control Panel to reset the alarm

Note

:  Resetting the station does not cancel the alarm at the 

panel