5964
CATALOG NUMBER
FIRE ALARM ADDRESSABLE MANUAL PULL STATIONS
MPS-800MP(U) SERIES
Description
Mircom’s MPS-800MP(U) Series Fire Alarm Manual Pull
Stations provide manual fire alarm activation. The new
MPS-800 Series uses raised symbols and icons instead of
printed text that makes them universally recognized.
These addressable pull stations are available as single or two
stage dual action devices. Compatible with FX-400 Series and
Flex-Net FX-4000 Fire Alarm Panels.
The MPS-800MP(U) manual stations are constructed of
high quality polycarbonate resin thermoplastic “LEXAN” that
supports high temperatures without deforming.
The MPS-800MP(U) addressable pull stations are accessible
from the front for wiring while mounted making it easy to install.
These pull stations can be mounted on a single gang backbox
and the mounting holes permit easy alignment to the wall.
The suffix “U” indicates USA version.
All manual fire alarm stations shall be installed as per the
specific requirements outlined in the UL/ULC codes, as well
as all other applicable national or local codes.
Addressing is done using the MIX-4090 Device Programmer.
For setting the address on this device, disconnect it from the
loop, or ensure that the loop to which is connected is both
disconnected from the panel and shorted across the SCL+ and
SLC- inputs at the device. Failing to take either of these steps
may change the address programming of previously configured
sensors on the loop.
Features
•
Completely made of LEXAN material
•
Closed-fist operation (ADA – Americans with Disability Act)
•
No printed text on the devices, symbols and icons are
used instead
•
Symbols are raised to be easily recognized by touch
•
Compatible with FX-400 Series and Flex-Net FX-4000 Fire
Alarm Panels
•
Easy installation
•
Accessible from the front for wiring while mounted
•
Mounts on a single gang backbox
•
Temperature range from 0ºC to 49ºC
•
UL and ULC listed
•
Device comes with a reset key
•
Indoor use only
•
Alarm LED is viewable from the front - Useful for trouble
shooting
MPS-810MP(U)
1 Stage
MPS-802MP
2 Stage
Operation
Activating the Alarm
•
Push in the push bar
•
Pull down the pull handle
Activating the stage two alarm (MPS-802MP and
MPS-822MP)
•
Insert the stage two key into the stage two keyhole, and
then turn the key.
•
The stage two alarm activates immediately.
Resetting the manual station
•
Insert the key into the reset keyhole and turn it.
•
Pull the cover open. The switch is now reset.
•
Close and lock the stations with the reset key.
•
Reset the Fire Alarm Control Panel to reset the alarm
Note
: Resetting the station does not cancel the alarm at the
panel