background image

1-888-750-1698

STAPLE YOUR RECEIPT HERE

TO OBTAIN SERVICE UNDER WARRANTY OR FOR ANY SERVICE RELATED QUESTIONS, please call:   

 

 

Venting Services (referred to herein as “we” or “us”) warrants to the original consumer purchaser (referred to herein as 
“you” or “your”) of range hoods (the “Products”) that such Products will be free from defects in materials or workmanship 
as follows:

One Year Limited Warranty for Parts:

  For one year from the date of your original purchase of the Products, we will 

provide, free of charge, Products or parts to replace those that failed due to manufacturing defects.  We may choose, in 
our sole discretion, to repair or replace parts before we elect to replace the Products.

One Year Limited Warranty for Labor:

  For one year from the date of your original purchase of the Products, we will 

provide, free of charge, the labor cost associated with repairing the Products or parts to replace those that failed due to 
manufacturing defects.  After the first year from the date of your original purchase, you are responsible for all labor costs 
associated with this warranty.

Warranty Exclusions: 

 This warranty covers only repair or replacement, at our option, of defective Products or parts 

and does not cover any other costs related to the Products including but not limited to: (a) normal maintenance and 
service required for the Products and consumable parts such as light bulbs, metal and carbon filters and fuses; (b) any 
Products or parts which have been subject to freight damage, misuse, negligence, accident, faulty installation or installa-
tion contrary to recommended installation instructions, improper maintenance or repair (other than by us); (c) commer-
cial use of the Products or use otherwise inconsistent with its intended purpose; (d) natural wear of the finish of the Prod-
ucts or wear caused by improper maintenance, use of corrosive and abrasive cleaning products, pads, and oven cleaner 
products; (e) chips, dents or cracks caused by abuse or misuse of the Products; (f) service trips to your home to teach 
you how to use the Products; or (g) damage to the Products caused by accident, fire, floods or act of God.  If you are 
outside our service area, additional charges may apply for shipping costs for warranty repair at our designated service 
locations and for the travel cost to have a service technician come to your home to repair, remove or reinstall the Prod-
ucts.  After the first year from the date of your original purchase, you are also responsible for all labor costs associated 
with this warranty.  

Limitations of Warranty.  OUR OBLIGATION TO REPAIR OR REPLACE, AT OUR OPTION, SHALL BE YOUR SOLE 
AND EXCLUSIVE REMEDY UNDER THIS WARRANTY.  WE SHALL NOT BE LIABLE FOR INCIDENTAL, CONSE-
QUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE OF 
THE PRODUCTS.  THE EXPRESS WARRANTIES IN THE PRECEDING SECTION ARE EXCLUSIVE AND IN LIEU OF 
ALL OTHER EXPRESS WARRANTIES.  WE HEREBY DISCLAIM AND EXCLUDE ALL OTHER EXPRESS WARRAN-
TIES  FOR THE PRODUCTS, AND DISCLAIM AND EXCLUDE ALL WARRANTIES IMPLIED BY LAW, INCLUDING 
THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.

   Some states or provinces do not 

allow limitations on the duration of an implied warranty or the exclusion or limitation of incidental or consequential dam-
ages, so the above limitations or exclusions may not apply to you.  To the extent that applicable law prohibits the exclu-
sion of implied warranties, the duration of any applicable implied warranty is limited to the same one-year period 
described above.  Any oral or written description of the Products is for the sole purpose of identifying the Products and 
shall not be construed as an express warranty.  Prior to using, implementing or permitting use of the Products, you shall 
determine the suitability of the Products for the intended use, and you shall assume all risk and liability whatsoever in 
connection with such determination.   We reserve the right to use functionally equivalent refurbished or reconditioned 
parts or Products as warranty replacements or as part of warranty service.  This warranty is not transferable from the 
original purchaser and applies in the United States and Canada.

To Obtain Service Under Limited Warranty:  

To qualify for warranty service, you must: (a) notify us at the address or 

telephone number stated below within 60 days of the discovery of the defect; (b) give the model number and part identifi-
cation number and serial number; and (c) describe the nature of any defect in the Product or part.  At the time of the 
request for warranty service, you must present evidence of your proof of purchase and proof of the original purchase 
date.  If we determine that the warranty exclusions listed above apply or if you fail to provide the necessary documenta-
tion to obtain service, you will be responsible for all shipping, travel, labor and other costs related to the services.

Venting Services PO Box 6188 Oakland, CA 94603 | 1-888-750-1698 | vsupport@ventingservices.com

Limited Warranty

MAY10.0101

Proof of the original purchase 

date is needed to obtain     

service under warranty

Summary of Contents for MH70130AS

Page 1: ...READ AND SAVE THESE INSTRUCTIONS Installation Use and Care Guide MODEL MH70130AS MH70136AS 2014 SEP ...

Page 2: ...www build com ...

Page 3: ...ight Clearance 6 Ducting Options 7 Specifications 8 Electrical 9 Mounting the Range Hood 10 Horizontal Conversion 11 12 FEATURES CONTROLS Rotary Dial 13 MAINTENANCE Cleaning and Filter Removal 14 Lights 15 TROUBLESHOOTING 16 WIRING DIAGRAMS 17 LIST OF PARTS AND ACCESSORIES 18 Table of Contents ...

Page 4: ...r the type of and amount of food being prepared WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP FIRE OBSERVE THE FOLLOWING a SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO PREVENT BURNS If the flames do not go out immediately EVACUATE AND CALL THE FIRE DEPARTMENT b NEVER PICK UP A FLAMING PAN You may be burned c D...

Page 5: ...s adequate and in conformance with National Electrical Code ANSI NFPA 70 latest edition or CSA standards C22 1 94 Canadian Electrical Code Part 1 and C22 2 No 0 M91 latest edition and all local codes and ordinances If codes permit and a separate ground wire is used it is recommended that a qualified electrician determine that the ground path is adequate Do not ground to a gas pipe Check with a qual...

Page 6: ... for horizontal ducting 1 7 round starting collar for vertical ducting 1 7 round metal cap for horizontal ducting 1 Hardware package HARDWARE PACKAGE CONTENTS PARTS NOT SUPPLIED Ducting conduit and all installation tools Cable connector if required by local codes Duct cover accessory Light Bulb Removal Suction Cup 1 M6 x 1 4 M6 x 1 1 2 4 M6 x 2 4 M4 x 6 11 Wire Caps 3 4 ø12 OD ø5 ID Washers ...

Page 7: ... Ft 6 Round straight 1 Ft x Ft Subtotal column 1 Duct pieces T otal Equivalent number length x used 6 Round wall cap with damper 30 Ft x Ft Round wall cap with damper 30 Ft x Ft 7 10 Round 900 elbow 15 Ft x Ft 7 10 7 10 Round 450 elbow 9 Ft x Ft Ft Ft Ft 6 Round roof cap 30 Ft x Ft 7 10 Round roof cap 30 Ft x Ft Subtotal column 2 Subtotal column 1 Total ductwork 6 roundto 3 1 4 x 10 rect transitio...

Page 8: ...ould be no higher than 34 It is important to install the hood at the proper mounting height Hoods mounted too low could result in heat damage and fire hazard while hoods mounted too high will be hard to reach and will lose its performance and efficiency If available also refer range manufacturer s height clearance requirements and recommended hood mounting height above range Vertical Ducting 7 round...

Page 9: ... attics or garages All exhaust must be ducted to the outside Use metal ductwork only Fasten all connections with sheet metal screws and tape all joints with certified Silver Tape or Duct Tape Some Ducting Options Installation Ducting Options Side wall cap w gravity damper Roof Pitch w Flashing Cap Rear Ducting ...

Page 10: ...8 www build com Installation Specifi cations 27 7 8 30 33 7 8 36 elec k o top side back 4 1 2 12 8 9 16 1 1 8 29 15 16 30 35 15 16 36 6 7 8 9 3 22 1 2 1 1 8 3 1 8 9 13 16 elec k o 3 7 16 1 15 16 3 1 3 16 ...

Page 11: ...ing local codes and ordinances Electrical Supply This appliance requires a 120V 60Hz electrical supply and connected to an individual properly grounded branch circuit protected by a 15 or 20 ampere circuit breaker or time delay fuse Wiring must be 2 wire w ground Please also refer Electrical Diagram labeled on product Cable Lock A cable locking connector not supplied might also be required by loca...

Page 12: ... the range hood in the desired mounting location Measure and mark the mounting holes duct and electrical locations with a pencil 5 Drill cut out the required openings for duct and electrical access make sure the duct opening is large enough to apply duct tape 6 Fasten hood onto cabinet with 4 M6 wood screws provided 7 Install electrical 8 Install duct work and duct tape 9 Reinstall baffle filters 10...

Page 13: ...d body and remove collar 4 Using plyers remove rectangular cover plate at back of hood body 5 Unscrew 4 screws holding blower to top of hood body 6 Remove blower from hood body and turn blower 180 degrees so that blower outlet faces the back of hood body Installation Horizontal Conversion 1 Unscrew 2 screws holding each left and right side bottom spacer panels and remove panels from hood body 2 Un...

Page 14: ...11 Place 7 round cover plate over top 7 round blower hole and secure by 3 M4 x 6 screws Installation Horizontal Conversion 7 Picture of blower turned 180 degrees 8 Position blower inside hood body so that the 4 blower mount nuts line up with the 4 screw holes at back of hood body 12 Re Install the left and right side bottom spacer panels and rear filter holder panel previously removed from steps 1 ...

Page 15: ... Off Speed Selection 2 Lights Dim Bright Off 1 Blower On Off Speed Selection 2 Lights Dim Bright Off Rotate dial to change speed levels 1 for low speed 2 for medium speed and 3 for high speed Rotate dial to change light settings 1 for dim light and 2 for bright light ...

Page 16: ...rub lightly using a micro fiber or clean cotton cloth and with grain Stainless Steel Baffle Filters The stainless steel baffle filters are intended to trap residue and grease from cooking Although the filters should never need replacing they are required to be cleaned every 30 days or more often depending on cooking habits Filters may be placed in dishwasher at low heat or soaked in hot soapy water Dry...

Page 17: ...rning bulb counter clockwise Note Bulb does not unscrew it turns 60 degrees stops and falls out If bulbs are difficult to turn due to prolonged use firmly attach a glass suction cup approximately the diameter of the bulb or use a rubber latex glove and turn counter clockwise Replacement bulbs are available at specialty lighting stores Purchase type MR16 GU 10 50W halogen For part numbers please turn...

Page 18: ...in place 1 Tighten the blower in place r e w o l b e h t e g n a h C 2 l e e h w r e w o l b d e g a m a D 2 3 The hood is not secured in place 3 Check the installation of the hood The blower is working but the lights are not b l u b n e g o l a h e h t e g n a h C 1 b l u b n e g o l a h e v i t c e f e D 1 b l u b t h g i l e h t n e t h g i T 2 e s o o l s i b l u b t h g i l e h T 2 3 The wire...

Page 19: ...17 Wiring Diagrams MH70130AS MH70136AS ...

Page 20: ... www build com DESCRIPTION PART Replacement Parts Light Bulb MR16 GU10 50W each Z0B 0020 To order parts email us at vsupport ventingservices com or call us at 1 888 750 1698 List of Parts and Accessories ...

Page 21: ... you are also responsible for all labor costs associated with this warranty Limitations of Warranty OUR OBLIGATION TO REPAIR OR REPLACE AT OUR OPTION SHALL BE YOUR SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY WE SHALL NOT BE LIABLE FOR INCIDENTAL CONSE QUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE OF THE PRODUCTS THE EXPRESS WARRANTIES IN THE PRECEDING SE...

Reviews: