10
Installation –
Horizontal Ducting Conversion
1. Disconnect both blower plugs.
A
3. Remove knock out plate A from back of hood
body using flat head screw driver and rubber
mallet.
4. Position dual blower at back of hood. Tuck dual
blower plate under blower clips and secure
blower to back of hood by (4) screws removed
from step 2.
5. Attach 10” round collar to back of hood body by
(4) M4 x 8 screws.
6. Attach top cover plate to top of hood body by (4)
3/16 x 3/8 screws.
2. Remove (4) screws attaching dual blower plate
to top of interior body of hood. Remove dual
blower from hood body.