41
ELECTRIC WIRE ROPE HOIST
XM SERIES
3. INSTALLATION INSTRUCTIONS
Verify the proper installation of the rope into
the socket and that the rope is not tight.
Check the stop limit switches for proper
position and fastening.
Verify the cable section of the power supply line,
in compliance with the current consumption of
the motors (as shown in Table 2-3-4-5 on page
40).
Verify tightening of all fastening screws on the
components.
Cable section for power supply trailing cable
Table 6
3.10 START-UP
Verify the function of the power supply line and
the capacity of the main line circuit breaker in
relation to the motor powers and the relevant
current consumption.
Make sure the gearboxes are lubricated and
there are no oil leaks.
Verify that rope, drum, pulleys and rope guide
are lubricated with grease grade SAE 30.
5
1
2
3
4
5
6
7
8
9
10
20
CORRENTE NOMINALE (A)
TENSIONE 400 V
LUNGHEZZA DEL CAVO (m)
50 mm²
35 mm²
25 mm²
16 mm²
10 mm²
6 mm²
4 mm²
2,5 mm²
30
40
50
60
70
80
90
100
200
6 7
30
8
10
9
40
80
60
50
200
20
Summary of Contents for XM SERIES
Page 2: ......
Page 71: ...71 Manual for installation operation and maintenance of the wire rope hoists XM Series NOTE ...
Page 72: ...72 Manual for installation operation and maintenance of the wire rope hoists XM Series NOTE ...
Page 73: ...73 Manual for installation operation and maintenance of the wire rope hoists XM Series NOTE ...
Page 74: ...74 Manual for installation operation and maintenance of the wire rope hoists XM Series NOTE ...
Page 75: ......