Sunlight shining on the panels will generate voltage, high voltage in
series may cause danger to life. Therefore, before connecting the DC
input line, the solar panel needs to be blocked by the opaque material
and ensure that the DC switch is 'OFF', otherwise, the high voltage of
the inverter may lead to life-threatening conditions.
After the DC terminal is connected, do not close the DC switch first. Connect the
AC terminal to the AC terminal of the inverter, the AC terminal is equipped with
three-phase AC terminals that can be conveniently connected. F lexible cords are
recommended for easy installation. The specifications are as shown in table 5.2
1. Matching socket 2.Sleeve 3.Sealing core 4.Sealing nut
Pic 5.7 AC connector structure
The AC output connector is divided into three parts: matching socket, sleeve
and sealing sleeve, as shown in Picture 5.7, the steps are as follows:
Step 1 Remove the cable sealing ring and sleeve in sequence from the ac
connector.
Step 2 Separate the sleeve from the matching socket, as shown in figure 5.7,
the connector body has two locking holes, and press the locking valve in the hole
inward to separate the matching socket from the sleeve.
Step 3 use strippers to strip the protective sheath and insulation layer of the
ac cable to the right length, as shown in Picture 5.8
Prohibit use a single circuit breaker for multiple inverters ,
prohibit the connection of load between inverter circuit
breakers.
Sheet 5.2 Cable information
Pic 5.8 Strip AC cable
Be careful to distinguish the L, N and PE of the AC cables.
Outside cable(3+PE)20m Outside cable(3+PE)20m
5.2 DC input terminal connection
Specification
Model
MMC6K/8K-G
16A/400V
MMC10K-G
25A/400V
Dia
Cable item
Cable
CSA
Cable
outer
dia
15~18mm
2.5mm 4mm
AWG
Dia
Cable
CSA
6mm
10
2.5mm
Cable
outer
dia
AWG
15~18mm
10
2
2
Breaker
Max cable
length
- 15 -
- 16 -
1
2
3
4
8~15mm