● Please select the wall with certain bearing capacity.
● When do the installation, vertical slope cannot /-15°.Make sure no
lateral tilt. Otherwise it will affect the function of the heat sink. Cause the output
power lower than expected.
● If install more than one inverter, must leave at least 500mm gap between each
inverter. And each inverter must leave at least 500mm from above and below. And
must install the inverter at the place where children cannot touch. Please see pic 4.3
● Consider whether the installation environment is helpful to see the inverter LCD
display and indicator status clearly.
● Must offer a ventilate environment if inverter is installed in the airtight house.
9GLKZ_.OTZY
Do not place or store any items next to the inverter.
Pic4.3 Installation Gap
Pic4.4 Inverter Installation
The inverter is designed according to the wall mounted type installation, please
use the wall mounted (the brick wall of the expansion bolt) when installing.
4.2 Inverter Installation
Pic4.2 Installation Angle
- 9 -
- 10 -
≥
500mm
≥
500mm
Anchoring
Mounting bracket
M4*14 Stainless steel screws
Inverter