TABLE OF CONTENTS

1. Safety Instructions

....................................................................................................1

2. Technical Specifications

..........................................................................................2

3. How To Control The Unit

......................................................................................3

4. Trouble shooting

.......................................................................................................7

5. Fixture Cleaning

........................................................................................................7

6

. Technical Support

....................................................................................................8

statement

The product has well capability and intact packing when leave factory. All of
the

user should comply with warning item and manual, any misuse cause of the

damages are not included in our guarantee, and also can not be responsible
for any malfunction & problem owing to ignore the manual.

1. Safety Instructions

Please keep this User Guide for future consultation. If you sell the unit to another user, be
sure that they also receive this instruction booklet.

Unpack and check carefully there is no transportation damage before using the unit.

Before operating, ensure that the voltage and frequency of power supply

match the power requirements of the unit.

It’s important to ground the yellow/green conductor to earth in order to avoid

electric shock.

The unit is for indoor use only. Use only in a dry location.

The unit must be installed in a location with adequate ventilation, at least

50cm from adjacent surfaces. Be sure that no ventilation slots are blocked.

Disconnect main power before replacement or servicing.

Make sure there are no flammable materials close to the unit while operating as it is fire

hazard.

Use safety cable when fixes this unit. DO NOT handle the unit by taking its head only, but

always by taking its base.

Maximum ambient temperature is Ta: 40

. DO NOT operate it where the temperature is

higher than this Unit surface temperature may reach up to 85

. DO NOT touch the housing

bare-hand during its operation. Turn off the power and allow about 15 minutes for the unit to
cool down before replacing or serving.

In the event of serious operating problem, stop using the unit immediately.Never try to
repair the unit by yourself. Repairs carried out by unskilled people can lead to damage

Summary of Contents for ML-ML28B

Page 1: ...56 10W 4in1 zoom moving head light User Manual ML ML28B ...

Page 2: ... requirements of the unit It s important to ground the yellow green conductor to earth in order to avoid electric shock The unit is for indoor use only Use only in a dry location The unit must be installed in a location with adequate ventilation at least 50cm from adjacent surfaces Be sure that no ventilation slots are blocked Disconnect main power before replacement or servicing Make sure there a...

Page 3: ...may require service please contact your nearest dealer Installation The unit should be mounted via its screw holes on the bracket Always ensure that the unit is firmly fixed to avoid vibration and slipping while operating And make sure that the structure to which you are attaching the unit is secure and is able to support a weight of 10 times of the unit s weight Also always use a safety cable tha...

Page 4: ... color macro effect Dimmer 0 100 smooth dimming Variable strobe effects Fast quiet operation and flicker free The lumen derails like below 10 1M 3M 5M R Lux 437 82 34 G Lux 5500 881 348 B Lux 4300 845 370 W Lux 4200 824 285 RGBW 10 Lux 14500 2655 893 RGBW 60 Lux 6 9 K 983 462 3 How To Control The Unit The DMX512 is widely used in intelligent lighting control with a DMX 512 controller connect sever...

Page 5: ...MENU Keys does not save and Exit function Address CH Value Set to Slave Auto program Music control Address001 XXX PAN Slave Master Auto Alone Auto Master Music Alone Music Change address Show each channel value Slave receive position select auto run mode Sound auto run inform Temp Inf Head Temperature XXX current tempreture Soft Inf V1 0 software version Person Status settings Pan Reverse Tilt Rev...

Page 6: ...ons and values 14 DMX channels DMX functions and their values 14 DMX channels Channel Value Function 1 PAN Movement 8bit 0 255 Pan Movement 2 Pan Fine 16bit 0 255 Fine control of Pan movement 3 TILT Movement 8bit 0 255 Tilt Movement 4 Tilt Fine 16bit 0 255 Fine control of Tilt movement 5 Red LED 0 255 Red 0 Black 255 100 Red 6 Green LED 0 255 Green 0 Black 255 100 Green 7 Blue LED 0 255 Blue 0 Bla...

Page 7: ...ovenment 8 bit 0 255 Zoom movement 13 Speed Pan Tilt movement 0 225 max to min speed 226 255 no function 14 reset internal programs 0 79 Normal 80 84 All motor reset 85 87 Scan motor reset 88 99 No function 100 119 Internal program 1 secne1 8 of EEPROM 2700k 120 139 Internal program 2 secne9 16 of EEPROM 3200k 140 159 Internal program 3 secne17 24 of EEPROM 4300k 160 179 Internal program 4 secne25...

Page 8: ...the unit or the previous one 4 Try to use another DMX controller 5 Check if the DMX cables run near or run alongside to high voltage cables that may cause damage or interference to DMX interface circuit C One of the channels is not working well 1 The stepper motor might be damaged or the cable connected to the PCB is broken 2 The motor s drive IC on the PCB might be out of condition 5 Fixture Clea...

Page 9: ... 6 Technical Support Support Telephone 86 20 62918259 Support Email sales2 gzmisslighting com Website www gzmisslighting com Working Time BeiJing Time Monday to Friday 08 00 12 00 14 00 18 00 19 00 21 00 Saturday 09 00 12 00 14 00 18 00 Note all the rest of China s holidays ...