Terminals (CN)
Voltage
Remarks
3-6-25
2AR-1
* Optional.
9-5
9-6
24 V DC
24 V DC supply for HVTPCB, output
9-7
9-6
0 – 5 V DC
TC control voltage, output
9-9
9-6
0/13 V DC
TC on/off, output
9-10
9-6
0 – 5 V DC
DB control voltage, output
9-11
9-6
0/23 V DC
DB on/off, output
9-12
9-6
0/5 V DC
MC ALM signal, input
9-13
9-6
0 – 15 V DC
GRID control voltage, output
9-14
9-6
0/18 V DC
MC on/off, output
10-A1
10-B9
24 V DC
24 V DC supply for CLM-U, output
10-A2
10-B9
0/24 V DC
CLM-U on/off, output
10-A3
10-B9
24 V DC
24 V DC supply for CLM-L, output
10-A4
10-B9
0/24 V DC
CLM-L on/off, output
10-A5
10-B9
0/24 V DC
RCL on/off, output
10-A6
10-B9
24 V DC
24 V DC supply for RCL, output
10-A7
10-B9
0/24 V DC
FCL1 on/off, output
10-A8
10-B9
24 V DC
24 V DC supply for FCL1, output
10-A9
10-B9
0/24 V DC
FCL2 on/off, output
10-A10
10-B9
24 V DC
24 V DC supply for FCL2, output
10-A11
10-B9
0/24 V DC
FCL3 on/off, output
10-A12
10-B9
24 V DC
24 V DC supply for FCL3, output
10-B1
10-B9
0/24 V DC
PFCL-U on/off, output
10-B2
10-B9
24 V DC
24 V DC supply for PFCL-U, output
10-B3
10-B9
0/24 V DC
PFCL-L on/off, output
10-B4
10-B9
24 V DC
24 V DC supply for PFCL-L, output
10-B5
10-B9
0/24 V DC
DUPCL* on/off, output
10-B6
10-B9
24 V DC
24 V DC supply for DUPCL*, output
10-B7
10-B9
0/5 V DC
DUPPCSW* on/off, input
10-B8
10-B9
5 V DC
5 V DC supply for DUPPCSW*, output
10-B11
10-B9
0/5 V DC
Duplex unit* connected signal, input
11-A1
11-A5
0/5 V DC (pulse)
DM drive clock pulse, output
11-A2
11-A5
0/5 V DC
DM LOCK signal, input
11-A3
11-A5
0/5 V DC
DM on/off, output
11-A4
11-A5
5 V DC
5 V DC supply for DM, output
11-A8, A9 11-A5
24 V DC
24 V DC supply for DM, output
11-B1
11-B8
5 V DC
5 V DC supply for LED*, output
11-B2
11-B8
0/5 V DC
LED* on/off, output
11-B3
11-B8
5 V DC
5 V DC supply for JOFSW*, output
11-B4
11-B8
0/5 V DC
JOFSW* on/off, input
11-B6
11-B8
0/5 V DC
Job separator* connected signal, input
11-B9
11-B8
5 V DC
5 V DC supply for JBESW*, output
Summary of Contents for PointSource Ai 3010
Page 1: ...3010 S M MCA SERVICE MANUAL Published in Apr 00 2AR70765 Revision 5 PointSource Ai 3010 R...
Page 2: ...Service Manual PointSource Ai 3010...
Page 13: ...3010 S M MCA THEORY AND CONSTRUCTION SECTION I I Theory and Construction Section...
Page 14: ...2AR CONTENTS 1 1 Specifications 1 1 1 Specifications 1 1 1...
Page 18: ...2AR CONTENTS 1 2 Handling Precautions 1 2 1 Drum 1 2 1 1 2 2 Developer and toner 1 2 1...
Page 61: ...3010 S M MCA ELECTRICAL SECTION II II Electrical Section...
Page 62: ...2AR CONTENTS 2 1 Electrical Parts Layout 2 1 1 Electrical parts layout 2 1 1 1 Copier 2 1 1...
Page 92: ...3010 S M MCA III Set Up and Adjustment Section III SET UP AND ADJUSTMENT SECTION...
Page 108: ...3 1 15 2AR This page has been left blank intentionally 2AR 5...
Page 136: ...3 2 11 2AR 1 This page is intentionally left blank...
Page 191: ...3 2 62 2AR 1 This page is intentionally left blank...
Page 196: ...3 2 61 2AR 1 This page is intentionally left blank...
Page 255: ...3 2 38 2AR 1 This page is intentionally left blank...
Page 384: ...2AR 1 3 6 15 This page is intentionally left blank...
Page 398: ...3 6 27 2AR 1 3 Main PCB CN9 CN5 CN2 CN3 CN4 IC11 IC12 CN1 CN8 CN10 CN11 CN6 CN7...
Page 431: ...2AR General connection diagram 3 7 43 General wiring diagram 3 7 44 2AR 1...