GEMINI 

ACTIVE INFRARED MINI BARRIER WITH DOUBLE LENS, DISPLAY 

AND 8 DIGITAL FREQUENCIES 

Available in three versions GEMINI 30, GEMINI 60 et GEMINI 100 

Installation and user manual 

MADE IN ITALY 

GEMINI - Rev. 08 - 03/2022 - MITECH srl reserves the right to change the information in this document without warning. 

Page 1 of 2 

GENERAL FEATURES 

Maximum range: 30 m - 

GEMINI 30

, 60 m - 

GEMINI 60

, 100 m - 

GEMINI 100 

Minimum range: 15 m - 

GEMINI 30

, 30 m - 

GEMINI 60

, 50 m - 

GEMINI 100 

8 digital frequencies 
Optical synchronization 
Aligning with the viewfinder  
Vertical detection angle: 20 ° 
Horizontal detection angle: 180 ° 

Operating temperature from -25 ° C to + 55 ° C 
Buzzer alarm  
Alarm signal threshold: 0.5 Volt 
Power supply 13.8 – 24 Vdc 
Maximum absorption 100 mA 
Dimensions: 170x80x80 cm 
Protection class: IP55  

DESCRIPTION OF TERMINAL BLOCK, DISPLAY AND COMMANDS OF RECEIVER  BARRIER 

 

 
 
 
 
 

 

DESCRIPTION OF TERMINAL BLOCK, DISPLAY AND COMMANDS OF TRANSMITTER BARRIER 

 
 
 
 
 

TAMP 

TAMP 

NC 

COM 

NO 

VIN 

GND 

HEAT 

HEAT

: not used 

GND

: - Vdc (from 12 to 24 Vdc) 

VIN

: + Vdc (from 12 to 24 Vdc) 

NO

 

/

 

COM

 

/

 

NC

: alarm output NC or NO 

TAMP

 

/

 

TAMP

: tamper output NC  

LEVEL 

GOOD 

ALARM 

SET 

GREEN LED: 

on = correct operation 
off = alarm status 

RED LED: 

on = alarm status 
off = correct operation 

Menu entry 

command 

to modify settings 

Commands 

for changing 

settings 

HEAT

: not used 

GND

: - Vdc (from 12 to 24 Vdc) 

VIN

: + Vdc (from 12 to 24 Vdc) 

TAMP

 

/

 

TAMP

: tamper output NC  

INSTALLATION - SIGNAL LEVEL CHECK / ALIGNMENT - CHANGE PARAMETERS 

INSTALLATION  

Fix the barriers so that they are aligned using  
the accessories supplied (template for fixing to the wall, 
brackets for pole fixing, screws and rubber caps waterproof),  
wire the terminal blocks and power the modules.

 

 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

SIGNAL LEVEL CHECK / ALIGNMENT 

 

88 

Frequency setting command 

The signal value is shown only on the display of the receiver profile.  
The minimum operating value is 0.5 V, below this value the barrier is in alarm (RED LED 
on and GREEN LED off). 
To obtain the best signal, orient the optical unit of the receiver in the direction of the 
transmitter and vice versa until the best possible value is obtained (the values are to be 
considered optimal if greater than 3 V). For vertical adjustments, use the adjustment 
screw, while for horizontal adjustments, turn the bracket. 
If necessary, help yourself with the viewfinder. 

Adjusting screw 

Adjustment bracket 

horizontal 

Viewfinder 

TAMP 

TAMP 

VIN 

GND 

HEAT 

SET 

The red LEDs indicate the set frequency 

(see the table on page 2) 

TEMPLATE 
FOR WALL FIXING 

BRACKET 

FOR POLE FIXING 

Summary of Contents for GEMINI 30

Page 1: ...ionamento corretto Comando ingresso menù modifica impostazioni Comandi modifica impostazioni HEAT non utilizzato GND Vdc da 12 a 24 Vdc VIN Vdc da 12 a 24 Vdc TAMP TAMP uscita tamper NC INSTALLAZIONE CONTROLLO LIVELLO SEGNALE ALLINEAMENTO MODIFICA PARAMETRI INSTALLAZIONE Fissare le barriere in modo che siano in asse utilizzando gli accessori in dotazione dima per il fissaggio a parete staffe per i...

Page 2: ...requenza impostata Premere due volte il comando sul display verrà visualizzato lo stato del parametro d 2 Utilizzando i comandi e modificare lo stato d1 ON display accesso d0 OFF display spento 3 Uscire dal menù premendo il comando per 4 5 secondi o comunque fino a quando non si sentirà un doppio bip Sul display si tornerà a visualizzare il valore segnale SET SET ON OFF buzzer parametro C solo su ...

Page 3: ...ation off alarm status RED LED on alarm status off correct operation Menu entry command to modify settings Commands for changing settings HEAT not used GND Vdc from 12 to 24 Vdc VIN Vdc from 12 to 24 Vdc TAMP TAMP tamper output NC INSTALLATION SIGNAL LEVEL CHECK ALIGNMENT CHANGE PARAMETERS INSTALLATION Fix the barriers so that they are aligned using the accessories supplied template for fixing to ...

Page 4: ...e command for 4 5 seconds or in any case until a double beep is heard The display will return to showing the signal value SET SET ON OFF display parameter d only on RX module 1 Enter the menu by pressing the control for 4 5 seconds or in any case until you hear a double beep the display will show the set frequency Press the control twice the display will show the status of parameter d 2 Using the ...

Reviews: