Service Bulletin SB229
SB229 rev. A
16 of 16
Original Instructions
e) Locate the blue XD24 terminal block. Remove the jumper from the
terminal block, if a jumper is present. Run wires as follows.
f) Locate the blue XDI terminal block. Run wires as follows.
Figure 19: Wired VFD
4. Gather the wires toward the bottom of the VFD. This keeps them from interfering
with the cover.
5. Place the front cover on the VFD. Tighten the two screws that hold the cover
using a Torx screwdriver.
Preparing the Press
1. Close the doors on the main electrical enclosure.
2. Turn the black and red disconnect switch on the right-hand door of the electrical
enclosure to the On position.
3. Remove the lock and tag, and restore power at the electrical service entry panel.
4. Resume operation of the press.
Terminal
1
2
3
4
5
Wire
SO6
42
XD24
Terminal
1
2
3
4
5
6
Wire
48
52
56
57
53
54
XDI