background image

2

Important Safety Instructions and Precautions

WARNING:DO NOT CONNECT DIRECTLY TO THE PUBLIC SWITCHED 

TELEPHONE NETWORK (PSTN). ANY CONNECTION OF THIS 

TELEPHONY DEVICE TO AN OFF PREMISE APPLICATION, AN OUT OF 

PLANT APPLICATION, ANY OTHER EXPOSED PLANT APPLICATION, OR 

TO ANY EQUIPMENT OTHER THAN THE INTENDED APPLICATION MAY 

RESULT IN A SAFETY HAZARD, AND/OR DEFECTIVE OPERATION, AND/

OR EQUIPMENT DAMAGE. “EXPOSED PLANT” MEANS WHERE ANY 

PORTION OF THE CIRCUIT IS SUBJECT TO ACCIDENTAL CONTACT 

WITH ELECTRIC LIGHTING OR POWER CONDUCTORS OPERATING AT 

A VOLTAGE EXCEEDING 300 V BETWEEN CONDUCTORS OR IS 

SUBJECT TO LIGHTNING STRIKES.
WARNING:THE SOCKET OUTLET, IF USED, SHALL BE LOCATED NEAR 

THE EQUIPMENT AND SHALL BE EASILY ACCESSIBLE BY THE USER.
WARNING:ONLY MITEL

®

 APPROVED AC POWER ADAPTER (P/N 

50005301) SHALL BE USED.
NOTE:

SOME IP TELEPHONY DEVICES DO NOT REQUIRE AN AC POWER 

ADAPTER. IF POWER OVER THE LAN IS AVAILABLE, IT SHALL BE COMPLIANT WITH 

IEEE 802.3af.

WARNING:THE HANDSET SUPPLIED WITH THE 5560 IPT IS NOT 

CERTIFIED FOR USE WITH ANY OTHER TELEPHONY DEVICE. USE OF 

THE HANDSET WITH ANY OTHER TELEPHONY DEVICE MAY HAVE THE 

POTENTIAL TO CAUSE HEARING LOSS IN THE EVENT OF A LIGHTNING 

STRIKE ON THE OUTSIDE PLANT WIRING.
When using your 5560 IPT, basic safety precautions should always be followed 

to reduce the risk of fire, electric shock and injury to persons, including the 

following:

•  Do not use this product near water, for example, near a bath tub, wash 

bowl, kitchen sink or laundry tub, in a wet basement or near a swimming 

pool.

•  Avoid using the 5560 IPT during an electrical storm. There may be a 

remote risk of electric shock from lightning.

•  Do not use the 5560 IPT to report a gas leak in the vicinity of a leak.

Maintenance and Repair: There are no user serviceable parts inside the 5560 

IPT. For repairs, return the 5560 IPT to an authorized Mitel dealer.

These notices may appear on the product or in the technical documentation:

This symbol may appear on the product:

Description

• The Mitel 5560 IPT® is supported by 3300 ICP MXe systems only. A 

limited number of 5560 IPTs are supported. Refer to the 3300 ICP 

Engineering Guidelines for more information.

• 5560 IPTs are LAN-powered.

Supporting Documentation

To access 5560 IPT- and system-specific documentation:
1.  In your browser, go to www.mitel.com.
2.  Move your cursor over Support and Services, and then select 

Documentation Library.

3.  From the drop-down list, select Guides.

4. Click User Guides. Navigate to Specialty Endpoints.

Installing a 5560 IPT (See Figure 

 )

Before installing your 5560 IPT, ensure that you are familiar with the following 

powering options: 
• An IEEE 802.3af PoE jack provides power to the 5560 IPT via a LAN 

cable. (The 5560 IPT receives Ethernet signals and power through the 

same cable.) To install, see Steps 

n

 and 

o

.

• An Ethernet power adapter provides power to the 5560 IPT via a LAN 

cable. The Ethernet power adapter is connected to the LAN via a 

separate LAN cable connected to a jack. (The 5560 IPT receives Ethernet 

signals and power through the same cable.) To install, see Steps 

n

 and 

o

.

NOTE:

 Use only qualified Mitel-supplied Ethernet power adapters.

n

Thread the LAN cable plug through the opening in the center back of the 

installed base unit, guide it through the channel on the bottom of the base 

unit and plug it into the leftmost LAN port (Port 1) on the back of the 5560 IPT 

as shown. (Note: the second LAN port is not functional for this release.)

NOTE:

If you are wall-mounting your 

5560 IPT

, do not thread the LAN cable through the 

base unit slot—connect the cable directly from the LAN port on the 

5560 IPT

 to 

the jack on the wall.

o

Plug the other end of the LAN cable into one of the following:
• a LAN-powered jack 

or

• the phone port of an Ethernet power adapter. Then, connect the 

Ethernet adapter to the LAN using a separate LAN cable, and plug the 

power adapter into an AC power outlet.

p

Thread the handset cord through the channel on the bottom of the base unit 

and up through the opening on the back of the installed base unit. Plug the 

handset cord into the handset port. 

NOTE:

 Headsets can be directly connected to the 5560 IPT using a 6-pin to 4-pin 

adapter (not included). Not all headsets are compatible for operation with the 

5560 IPT.

Registering a 5560 IPT

To register an installed 5560 IPT in MiNET mode: 

•When prompted, enter a valid PIN and then press HOLD. 

When  registration is complete, you can connect a PC to the PC port on the back 

of the 5560 IPT. If desired, thread the PC cable through the slot on the back of 

the installed base unit, as shown for the LAN cable in Figure A, step 

n

 above. 

Desktop Mounting a 5560 IPT (See Figure 

 )

Turn the 5560 IPT so that the front faces away from you and locate the 

adjustment handles on either side of the 5560 IPT stand. 

n

Push the handles away from you (towards the front of the terminal) to 

loosen. 

o

Tilt the 5560 IPT stand to the desired position and then pull the adjustment 
handles toward you (towards the back of the terminal) to tighten them again.

Wall Mounting (See Figure 

 )

NOTE:

Wall mounting requires the use of a 1/8” (3mm) hex key.

n

Select a location away from electrical cables, pipes or other items that could 

cause a hazard when inserting screws in the wall.

CAUTION: Ensure the wall is capable of supporting the weight of the 5560 

IPT. For additional security, it is recommended that you mount the 5560 IPT on 

a plywood backboard. Mitel is not responsible for 5560 IPTs damaged as a 

result of improper wall mounting.

o

Use a hex key to remove the five screws on the top side of the stand. Retain 

these screws as you will need them in step 7.

p

Remove the bottom plate from the stand.

DANGER Danger indicates an imminently hazardous situation which, if not 

avoided, will result in death or serious injury.

WARNING Warning indicates a potentially hazardous situation which, if not 

avoided, could result in death or serious injury.

CAUTION

Caution indicates a potentially hazardous situation which, if not 

avoided, may result in minor or moderate injury and/or damage 

to the equipment or property.

The exclamation point within an equilateral triangle indicates that 

important operating and maintenance (servicing) instructions are 

included in the literature accompanying the product.

!

A

B

C

Summary of Contents for 5560 IPT none

Page 1: ...Installation Guide 5560 ...

Page 2: ...T receives Ethernet signals and power through the same cable To install see Steps n and o NOTE Use only qualified Mitel supplied Ethernet power adapters nThread the LAN cable plug through the opening in the center back of the installed base unit guide it through the channel on the bottom of the base unitandplugitintotheleftmostLANport Port1 onthebackofthe5560IPT as shown Note the second LAN port i...

Page 3: ...014 pleasecontacttheRegulatoryApprovalsManagerattheabove address Précautions et consignes importantes en matière de sécurité Canada AVERTISSEMENT NE CONNECTEZ PAS VOTRE APPAREIL DIRECTEMENT AU RÉSEAU TÉLÉPHONIQUE PUBLIC COMMUTÉ RTPC TOUTE CONNEXION DE CE TÉLÉPHONE À UNE INSTALLATION HORS LIEUX À UNE INSTALLATION HORS RÉSEAU À TOUTE AUTRE INSTALLATION D UN RÉSEAU NON PROTÉGÉ OU À TOUT ÉQUIPEMENT AU...

Page 4: ... ESTÉ EXPUESTA A UN POSIBLE CONTACTO CON RELÁMPAGOS O CONDUCTORES DE CORRIENTE QUE FUNCIONEN A UN VOLTAJE QUE EXCEDA LOS 300V ENTRE CONDUCTORES O ESTÉ EXPUESTA A DESCARGAS ELÉCTRICAS DE RAYOS ADVERTENCIA SI SE UTILIZA UN ENCHUFE DE TOMACORRIENTE ÉSTE SE DEBE UBICAR CERCA DEL EQUIPO Y EL USUARIO DEBE TENER UN FÁCIL ACCESO A ÉL ADVERTENCIA SÓLO SE USARÁN ADAPTADORES DE CA APROBADOS POR MITEL NOTA AL...

Page 5: ...O EXPOSTA SIGNIFICA QUE ALGUMA PARTE DO CIRCUITO ESTÁ SUJEITA A CONTATO ACIDENTAL COM FAÍSCAS ELÉTRICAS OU CONDUTORES DE ENERGIA OPERANDO EM UMA TENSÃO QUE EXCEDA 300 V ENTRE CONDUTORES OU ESTÃO SUJEITOS A RAIOS ADVERTÊNCIA A TOMADA SE USADA DEVE ESTAR LOCALIZADA PERTO DO EQUIPAMENTO E DEVE SER FÁCIL DE SER ACESSADA PELO USUÁRIO ADVERTÊNCIA SOMENTE OS ADAPTADORES DE ALIMENTAÇÃO CA APROVADOS DA MIT...

Page 6: ...ALS 300 V ZWISCHEN LEITERN AUFWEISEN ODER IN DIE DER BLITZ EINSCHLAGEN KANN WARNUNG DIE STECKDOSE FALLS VERWENDET MUSS SICH IN DER NÄHE DES GERÄTS BEFINDEN UND FÜR DEN BENUTZER LEICHT ZUGÄNGLICH SEIN WARNUNG NUR MITEL WECHSELSTROM NETZADAPTER DÜRFEN VERWENDET WERDEN HINWEIS EINIGE IP TELEFONE BENÖTIGEN KEINEN WECHSELSTROM NETZADAPTER WENN DIE STROMVERSORGUNG ÜBER EIN LAN GEMÄSS DEM STANDARD IEEE 8...

Page 7: ...SCHUWING ALS U EEN STOPCONTACT GEBRUIKT MOET HET ZICH DICHTBIJ DE APPARATUUR BEVINDEN EN MAKKELIJK BEREIKBAAR ZIJN VOOR DE GEBRUIKER WAARSCHUWING GEBRUIK ALLEEN DOOR MITEL GOEDGEKEURDE WISSELSTROOMADAPTERS VOOR SOMMIGE IP TELEFOONS IS GEEN WISSELSTROOMADAPTERS NODIG ALS ZE WORDEN GEVOED VIA EEN LAN MET EEN VOEDINGSBRON DIE VOLDOET AAN IEEE 802 3af OPMERKING VOOR SOMMIGE IP TELEFOONS IS GEEN WISSEL...

Page 8: ...tworks Corporation Todos los derechos reservados Marca registrada da Mitel Networks Corporation Copyright 2007 Mitel Networks Corporation Todos os direitos reservados Marke der Mitel Networks Corporation Copyright 2007 Mitel Networks Corporation Alle Rechte vorbehalten Marchio di Mitel Networks Corporation Copyright 2007 Mitel Networks Corporation Tutti i diritti riservati Handelsmerk van Mitel Ne...