Installation
160
Aastra 470 as of R3.2
syd-0337/1.6 – R3.2 – 09.2014
4. 7. 6
Ethernet interfaces
The communication server Aastra 470 has a Gbit Ethernet switch on the call man-
ager card. Three LAN interfaces are routed to the front panel of the call manager
card and labelled accordingly. The RJ45 sockets are highlighted in colour in the fig-
ure below.
Fig. 70
Connection possibilities for Ethernet interfaces
Note
Circuit type as per EN/IEC 60950: SELV
Socket
Tab. 75
Connection of Ethernet interfaces
Settings
The IP address can either be taken from a DHCP server in the IP network or config-
ured statically. If a DNS server is used, the communication server can also be ad-
dressed via its host name.
Tab. 76
Default values, IP address
RJ45 socket
Pin
Signal
1
TX D1+
2
TX D1–
3
RX D2+
4
BI D3+
5
BI D3–
6
RX D2–
7
BI D4+
8
BI D4–
Parameter
Parameter value
IP address
192.168.104.13
Subnet mask
255.255.255.0
Gateway
0.0.0.0
DHCP
yes
Host name
<Model name>-<MAC-Address>
1)
Example: Aastra430-00085d803100
1)
This entry is hidden and does not appear in the parameter’s input field