85
Basic Programming
Setting up RADs
Before you begin,
•
determine how the customer intends to use the RADs.
•
map the expected call flow to determine how many messages are
required and the order of play.
•
script the messages and say them several times to ascertain how
much time they take.
•
verify that sufficient voice mail ports and DSP resources are available;
see DSP configurations, page 11.
To program RADs:
1.
Form 04, System Options/System Timers
-
Enable System Option 134, Recorded Announcement Devices.
2.
Record RAD greetings
-
Access the System Administrator's mailbox (see Using the
Administrator’s Mailbox, page 88.)
-
Press 8 to select the RAD Greetings menu.
-
Press 1 to record a greeting.
-
Select RAD greeting number to record (1- 200).
Note:
All embedded voice mail ports can operate as dedicated RAD ports.
However, at least one non-RAD port is required to record RAD greetings; to
administer the voice mail system by telephone; and for message notification
by pager.
When configuring voice mail ports, ensure that some of the last ports
are not configured as RAD ports to avoid any potential conflicts with
message notification. It is recommended that at least two or three
ports be left free for message notification dependant upon system
usage. Embedded voice mail will attempt to use the last
programmed voice mail port that is available for message
notification. If the last port is not available, the second last port will
be attempted and if that port is busy, the third last port and so on.
Embedded voice mail will continue in this fashion until it finds a free
port but message notification will not function properly on a port
assigned to RAD.
Summary of Contents for SX-200 ICP - 1.0 5020
Page 1: ...Release 4 0 CX CXi Controller TECHNICIAN S HANDBOOK ...
Page 9: ...Chapter 1 Introduction ...
Page 10: ...2 SX 200 ICP CX CXi Technician s Handbook ...
Page 24: ...16 SX 200 ICP CX CXi Technician s Handbook ...
Page 25: ...Chapter 2 Basic Installation ...
Page 26: ...18 SX 200 ICP CX CXi Technician s Handbook ...
Page 75: ...Chapter 3 Basic Programming ...
Page 76: ...68 SX 200 ICP CX CXi Technician s Handbook ...
Page 89: ...81 Basic Programming The keys on the 5412 PKM are numbered as follows ...
Page 98: ...90 SX 200 ICP CX CXi Technician s Handbook Figure 10 Administrator Mailbox Menu ...
Page 142: ...134 SX 200 ICP CX CXi Technician s Handbook ...
Page 143: ...Chapter 4 Advanced Installation and Programming ...
Page 144: ...136 SX 200 ICP CX CXi Technician s Handbook ...
Page 183: ...Chapter 5 Routine Maintenance ...
Page 184: ...176 SX 200 ICP CX CXi Technician s Handbook ...
Page 219: ...Chapter 6 Basic Troubleshooting and Repair ...
Page 220: ...212 SX 200 ICP CX CXi Technician s Handbook ...
Page 245: ...Chapter 7 Advanced Troubleshooting and Repair ...
Page 246: ...238 SX 200 ICP CX CXi Technician s Handbook ...
Page 269: ...Appendix A Default Database Values ...
Page 270: ...262 SX 200 ICP CX CXi Technician s Handbook ...
Page 326: ...318 SX 200 ICP CX CXi Technician s Handbook ...
Page 327: ...Appendix B Part Numbers ...
Page 328: ...320 SX 200 ICP CX CXi Technician s Handbook ...
Page 336: ...328 SX 200 ICP CX CXi Technician s Handbook ...
Page 337: ...Appendix C System Cabling ...
Page 338: ...330 SX 200 ICP CX CXi Technician s Handbook ...
Page 343: ...Appendix D Folio Views E Docs Tips ...
Page 344: ...336 SX 200 ICP CX Technician s Handbook ...