TA7102 Hardware Installation
28
153/1531-ANF 901 14 B 2017-03-08
Table 7:
RESET/DEFAULT Button Interaction
RESET/ DEFAULT
Button Pressed for:
Action
Comments
LEDs Pattern
2 to 6 seconds
Restarts the
TA7102
No changes are made to the
TA7102 settings.
Power
LED:
• blinking, 1Hz,
50% duty
All other LEDs:
• OFF
7 to 11 seconds
Sets the TA7102
in Partial
Reset Mode
Sets some of the TA7012
configuration to pre-
determined values.
All LEDs
• blinking, 1Hz,
50% duty
12 to 16 seconds
Restarts the
TA7102 in Factory
Reset
Deletes the persistent
configuration, creates a new
configuration file with the
default factory values, and
then restarts the unit.
All LEDs
• steady ON
17 seconds and more
No action is taken
The RESET/DEFAULT
Button
Pressed event is ignored
N/A
At Start-Time
You can use the
RESET/DEFAULT
button at start-time
– you power the unit off, and then depress the
button until the LEDs stop blinking and remain ON. This applies the “Factory Reset” procedure (see
Factory Reset
). This feature reverts the TA7102 back to its default factory settings.