15
SECTION 3
OPERATION
3.1 CONTROLS
3.1.1 EXTERNAL CONTROLS
For a description of the front panel keys and select switches see Paragraph 3.2.1.
AC Power
Use the rear panel power on/off switch to control AC power to the unit.
Fuse
The fuse is accessible from the top cover of the unit, near the rear panel, in the corner where
the AC input is located. The fuse value is T1.25A.
3.1.2 INTERNAL CONTROLS
Power Supply Output Voltage Adjustment
Power supply voltages are adjusted from potentiometers located on the power supply.
Adjustment should be made using an insulated tuning tool. Voltage tolerances are +5.3 ± 0.2V,
+5.3 ± 0.2V and +15.3 ± 0.25V. There is no adjustment for the –15.3V output.
Figure 3-1. Internal Power Supply Adjustment
3.2 FRONT PANEL OPERATIONS
A Liquid Crystal Display (LCD) and Light Emitting Diode (LED) indicators have been organized
such that important information is available at a glance. The keyboard is divided into functional
groups to allow an operator to easily change any parameter from the front panel. See Figure 1-
1 for the physical layout of the front panel.
The green “POWER” LED is lit when power is on.
The red “ALARM” LED indicates an active alarm. The alarm LED lights amber when no alarms
are active but alarms have been recorded in the log. This LED does not light when no alarms
are active and the log has been cleared.
The green “REMOTE” LED is lit when the unit is under remote control and is off while the unit is
under local control.
POWER SUPPLY
ADJUSTMENT POTENTIOMETERS
AND TEST POINTS
MITEQ # 135782
+15.3V
+5.3V "A"
+5.3V "B"