!
!
20!
Counter!flow!pipe!heat!exchanger!(optional!equipment)!is!used!to!cool!down!hot!
wort! after! whirlpool! is! done.! For! proper! use! of! heat! exchanger! cold! water! is!
connected!to!valve!“
17.% Cold% water% inlet
”!and!hot!water!from!“
18.% Hot% water%
outlet
”!valve!is!suggested!for!using!for!next!batch.!
%
!
!
19.%Water%for%heating%inlet%
20.%Air%outlet%
21.%Safety%outlet%
%
%
!
Brewiks!uses!hot!water!under!pressure!as!heating!medium.!So!inside!of!heating!
system!must!always!be!water!more!then!1!bar!of!pressure.!Valve!“
19.%Water%for%
heating%inlet
“!is!used!to!fill!water!in!heating!system.!How!to!fill!water!in!heating!
system!please!read!more!in!chapter!8.!Before!the!first!use.!Valve!“
20.%Air%outlet
”!
is! used! for! air! to! go! out! of! heating! system.! If! in! any! case! pressure! in! heating!
system! exceed! 3! bar! then! valve! “
21.% Safety% outlet
”! open! and! pressure! is!
released.!
%
!
!
22.%Hot%external%inlet%
23.%Hot%external%outlet%
Summary of Contents for Brewiks 500
Page 1: ... Users manual for Brewiks 500 USA v 2 0 ...
Page 2: ... ...
Page 31: ... 31 Step 5 Pump wort to lauter tun Step 6 Recirculation Step 7 Lautering ...
Page 32: ... 32 Step 8 Boil Step 9 Add hops ...
Page 33: ... 33 Step 10 Whirlpool Step 11 Cooling the wort Step 12 Add yeast to fermentation tank ...