Physical installation
13
Unit placing
Adapter (180 Series)
Can be located on the back side of the LED units in
either orientation as below. Fix them with two
screws supplied with the adapters.
Power unit (160 Series)
If the power units are put on end, they should be
placed horizontally long, not vertically long due to
safety reason.
Control unit
The control units can be placed only flat.
Work space for installation
Keep necessary work space for the LED unit
installation.
Back side
When installing the base stand, leave a space
behind the LED wall as described below or wider.
In addition to that, if there is no dedicated air-
cooling equipment behind, leave about 20 cm
spaces above and underneath the LED wall for
ventilation.
If the ventilation space is less, forcibly exhaust the
hot air with an air-cooling device.
Surrounding (front models)
All the installation work for the front maintenance
models can be done from the front such as LED unit
connection or cabling behind the units. Leave the
following surrounding space for the ease of work.
(An example to start from left to spread to right)
10 cm
30 cm
20 cm
Adapter
20 cm