Electrical adjustment
19
Electrical adjustment
1.
Initial setting
DIP switch on power unit (160 Series)
Set the DIP switch on the power unit adequately
according to system configurations.
Cycle the main power switch to apply the
change.
No. Name
Function
Default
1
ID 1
Power unit ID setting
On
2
ID 2
Off
3
ID 4
4
ID 8
5
Reserved
No use
Off
6
Reserved
7
Reserved
8
Terminate
On: terminated
Off
Unit ID setting
Assign unique ID numbers on the power units
connected to each control unit. The initial setting is
ID 1. Up to 16 of ID numbers can be assigned with
the DIP switches #1 to 4.
Assign always from ID 1. For instance, when you
use 2 control units, each of which has 3 power
units (6 power units in total), assign ID 1 to ID 3
for each.
ID
1 2 3 4
ID
1 2 3 4
1
9
2
10
3
11
4
12
5
13
6
14
7
15
8
16
Termination setting
With the DIP switch #8, terminate the last power
unit in the cascading loop (p. 12). The initial setting
is non-terminated.
Terminated