48
NP180/160 Series Setup Manual
Status indicators
Control unit
The combination of 2 indicators shows a type of
malfunction.
You can identify which power unit (160 Series) or LED unit
has a failure in the “error information” tab in Wallaby
(p. 47).
Indicators
Status
On
Blinking
1
2
An LED unit
A power unit
(160 Series)
The control
unit
An LED unit
A power unit
(160 Series)
The control
unit
1
Blue
Blue
starting-up
Normal
N/A
2
Green
Off
standby
3
Green
Green
In operation
4
Red
Green
Failure(s)
Normal
5
Green
Red
6
Red
Red
7
Purple
Off
Standby due
to failure(s)
8
Off
Purple
9
Purple
Purple
Power unit (160 Series)
The power unit includes 4 power modules inside (5 modules in
the optional redundant power supply, S-NP15PWR-EX). If one
of the power modules fails, the corresponding indicator goes
off.
The S1 and S2 indicate the standby power.
Lighting either of them shows one of the power cords doesn’t
supply the power correctly or one of two standby power
circuits fails. Check if both power cords are surely connected.
Even if a standby power circuit has failed, the power unit can
properly supply the power to the LED units.
S1, S2 ON
P1 to P4 ON
P1 to P5 ON
Behavior
S-NP15PWR
Standby
Normal
If one of the modules fails, the power unit shuts down.
S-NP15PWR-EX
Normal
Even if one of the modules fails, the power unit keeps working.
Summary of Contents for 12NP180 Series