6 - 34 6 - 34
MELSEC-GOT
6 HANDLING
6.14 Attachment
The attachment is used to replace the A77GOT, GOT800 Series with the GOT-A900
Series.
By the use of the attachment, additional machining to the installation hole in the control
panel of the A77GOT, GOT800 Series can be eliminated.
6.14.1 Attachment types
The following Attachment type are available.
Type
Model in use
Applicable model
A77GT-96ATT
A77GOT-L, A77GOT-L-S3, A77GOT-L-S5, A77GOT-CL,
A77GOT-CL-S3, A77GOT-CL-S5
A960GOT
A87GT-96ATT
A77GOT-EL, A77GOT-EL-S3, A77GOT-EL-S5, A870GOT-EWS,
A8GT-70GOT-EW, A8GT-70GOT-EB
A960GOT
A87GT-97ATT
A870GOT-SWS, A8GT-70GOT-SW, A8GT-70GOT-SB,
A870GOT-TWS, A8GT-70GOT-TW, A8GT-70GOT-TB
A975/970GOT
6.14.2 Mounting procedure
1) Peel off the pressure sensitive adhesive double
coated tape from the rear surface of the
attachment.
Installation panel
Attachment
2) Install the attachment securely taking care so
that it is positioned correctly in the installation
panel mounting hole.
If the installation panel is dirty, the attachment
may fall, causing injury.
Ensure to clean the installation panel by wiping it
off before installation of the attachment.
GOT
Installation panel
3) Insert the GOT main unit from the front of the
attachment, and tighten it to the specified torque
using the mounting screws furnished with the
GOT main unit.
• The attachment can be used when the plate thickness of the installation panel is
1.2 (0.05) to 3 mm (0.12 in).
When the plate thickness exceeds 3 mm (0.12 in), the attachment cannot be
used for the replacement of the GOT.
• Once the GOT has been replaced with a new GOT by the use of the
attachment, the new GOT does not meet the requirements specified in the
standards for water and dust resistance IP65F, IP67F and NEMA4.