M800/M80/E80/C80 Series Alarm/Parameter Manual
14 Multi CPU Errors (A) [C80]
181
IB-1501279-H
Details
There is a mounted module that is not supported, or there is a mounted module that is not supported by
the network type (module model name) set in system parameters ("I/O Assignment Setting").
Remedy
Remove the unsupported module if any.
Check whether modules are supported by the network type (module model name) set in the system pa-
rameters.
If all the modules are supported, the possible cause is a hardware failure of the CPU module, base unit, I/
O module, or intelligent function module. Please consult your local Mitsubishi representative.
Details
In the multiple CPU system, the control CPU of the Q series intelligent function module incompatible with
the multiple CPU system is set to other than CPU No.1.
Remedy
Replace the Q series intelligent function module with the one (function version B) compatible with the mul-
tiple CPU system.
Set the control CPU of the Q series intelligent function module incompatible with the multiple CPU system
to CPU No.1.
Details
The number of CPU modules set in the system parameters ("I/O Assignment Setting") differs from the
number of CPU modules actually mounted.
The CPU module is mounted on the slot different from the one specified in the system parameters (I/O
assignment setting).
Remedy
Correctly set the number of CPU modules (including the empty setting) in the system parameters in accor-
dance with the number of CPU modules actually mounted.
Correctly set the system parameters so that the setting and actual CPU module mounting status will be
the same.
Details
The CPU module is not mounted on the slot that is set for the CPU module in the system parameters ("I/
O Assignment Setting").
The CPU module is mounted on the slot that is set for empty in the system parameters ("I/O Assignment
Setting").
An I/O module or intelligent function module is mounted between the CPU modules.
Remedy
Correctly set the number of CPU modules (including the empty setting) in the system parameters in accor-
dance with the number of CPU modules actually mounted.
Remove the I/O module or intelligent function module mounted between the CPU modules.
Details
The CPU module is mounted on the inapplicable slot.
Remedy
Mount the CPU module on the applicable slot (CPU slot or I/O slot 0 to 6).
Remove the CPU module from the inapplicable slot.
A01
Module configuration error
2020
A01
CPU module configuration error
2021
A01
CPU module configuration error
2040
A01
CPU module configuration error
2041
A01
CPU module configuration error
2043
Summary of Contents for C80 Series
Page 1: ......
Page 7: ......
Page 11: ......
Page 13: ......
Page 15: ......
Page 18: ...1 IB 1501279 H Alarm ...
Page 19: ...M800 M80 E80 C80 Series Alarm Parameter Manual 2 IB 1501279 H ...
Page 20: ...1 3 IB 1501279 H Operation Errors M ...
Page 54: ...2 37 IB 1501279 H Stop Codes T ...
Page 62: ...3 45 IB 1501279 H Servo Spindle Alarms S ...
Page 81: ...M800 M80 E80 C80 Series Alarm Parameter Manual 3 Servo Spindle Alarms S 64 IB 1501279 H ...
Page 82: ...4 65 IB 1501279 H MCP Alarms Y ...
Page 98: ...5 81 IB 1501279 H System Alarms Z ...
Page 111: ...M800 M80 E80 C80 Series Alarm Parameter Manual 5 System Alarms Z 94 IB 1501279 H ...
Page 112: ...6 95 IB 1501279 H Absolute Position Detection System Alarms Z7 ...
Page 118: ...7 101 IB 1501279 H Distance coded Reference Scale Errors Z8 ...
Page 120: ...8 103 IB 1501279 H Emergency Stop Alarms EMG ...
Page 124: ...9 107 IB 1501279 H Computer Link Errors L ...
Page 126: ...10 109 IB 1501279 H User PLC Alarms U ...
Page 136: ...11 119 IB 1501279 H Network Service Errors N ...
Page 139: ...M800 M80 E80 C80 Series Alarm Parameter Manual 11 Network Service Errors N 122 IB 1501279 H ...
Page 140: ...12 123 IB 1501279 H Program Errors P ...
Page 178: ...13 161 IB 1501279 H Smart Safety Observation Alarm V ...
Page 192: ...14 175 IB 1501279 H Multi CPU Errors A C80 ...
Page 215: ...M800 M80 E80 C80 Series Alarm Parameter Manual 14 Multi CPU Errors A C80 198 IB 1501279 H ...
Page 216: ...199 IB 1501279 H Parameter ...
Page 217: ...M800 M80 E80 C80 Series Alarm Parameter Manual 200 IB 1501279 H ...
Page 218: ...15 201 IB 1501279 H User Parameters ...
Page 359: ...M800 M80 E80 C80 Series Alarm Parameter Manual 15 User Parameters 342 IB 1501279 H ...
Page 360: ...16 343 IB 1501279 H Machine Parameters ...
Page 748: ......