M800/M80/E80/C80 Series Alarm/Parameter Manual
14 Multi CPU Errors (A) [C80]
184
IB-1501279-H
Details
The parameter setting is corrupted.
Remedy
Check the detailed information (parameter information) of the error by executing module diagnostics using
the engineering tool, and write the displayed parameter setting to the CPU module. If the same error code
is displayed again, the possible cause is a hardware failure of the data memory in the CPU module, the
memory card, or the module (I/O module or intelligent function module) connected. Please consult your lo-
cal Mitsubishi representative.
Details
The set value is out of range.
Remedy
Check the detailed information (parameter information) of the error by executing module diagnostics using
the engineering tool, and correct the parameter setting corresponding to the displayed number. If the same
error code is displayed again, the possible cause is a hardware failure of the data memory in the CPU mod-
ule, the memory card, or the module (I/O module or intelligent function module) connected. Please consult
your local Mitsubishi representative.
Details
Use of the function that is not supported by the module is enabled in parameter.
Remedy
Check the detailed information (parameter information) of the error by executing module diagnostics using
the engineering tool, and correct the parameter setting corresponding to the displayed number. If the same
error code is displayed again, the possible cause is a hardware failure of the data memory in the CPU mod-
ule, the memory card, or the module (I/O module or intelligent function module) connected. Please consult
your local Mitsubishi representative.
Details
A memory area cannot be ensured.
Remedy
Check the detailed information (parameter information) of the error by executing module diagnostics using
the engineering tool, display the error-detected area by clicking the [Error Jump] button, and increase the
capacity of the area. (If the capacity of the area cannot be increased, decrease the capacity of other areas.)
Reduce the number of labels or local devices used.
Details
The CPU module model set to the project using the engineering tool differs from that of the CPU module
actually mounted.
The operation set in the memory card parameters cannot be performed. (The boot function cannot be ex-
ecuted.)
Remedy
Correct the CPU module model set to the project in accordance with the CPU module actually mounted.
Delete the memory card parameter settings.
Remove the memory card so that the operation set in the memory card parameters will not be performed.
(Do not execute the boot operation.)
A01
Parameter A error
2220
A01
Parameter A error
2221
A01
Parameter A error
2222
A01
Parameter A error
2224
A01
Parameter A error
2225
Summary of Contents for C80 Series
Page 1: ......
Page 7: ......
Page 11: ......
Page 13: ......
Page 15: ......
Page 18: ...1 IB 1501279 H Alarm ...
Page 19: ...M800 M80 E80 C80 Series Alarm Parameter Manual 2 IB 1501279 H ...
Page 20: ...1 3 IB 1501279 H Operation Errors M ...
Page 54: ...2 37 IB 1501279 H Stop Codes T ...
Page 62: ...3 45 IB 1501279 H Servo Spindle Alarms S ...
Page 81: ...M800 M80 E80 C80 Series Alarm Parameter Manual 3 Servo Spindle Alarms S 64 IB 1501279 H ...
Page 82: ...4 65 IB 1501279 H MCP Alarms Y ...
Page 98: ...5 81 IB 1501279 H System Alarms Z ...
Page 111: ...M800 M80 E80 C80 Series Alarm Parameter Manual 5 System Alarms Z 94 IB 1501279 H ...
Page 112: ...6 95 IB 1501279 H Absolute Position Detection System Alarms Z7 ...
Page 118: ...7 101 IB 1501279 H Distance coded Reference Scale Errors Z8 ...
Page 120: ...8 103 IB 1501279 H Emergency Stop Alarms EMG ...
Page 124: ...9 107 IB 1501279 H Computer Link Errors L ...
Page 126: ...10 109 IB 1501279 H User PLC Alarms U ...
Page 136: ...11 119 IB 1501279 H Network Service Errors N ...
Page 139: ...M800 M80 E80 C80 Series Alarm Parameter Manual 11 Network Service Errors N 122 IB 1501279 H ...
Page 140: ...12 123 IB 1501279 H Program Errors P ...
Page 178: ...13 161 IB 1501279 H Smart Safety Observation Alarm V ...
Page 192: ...14 175 IB 1501279 H Multi CPU Errors A C80 ...
Page 215: ...M800 M80 E80 C80 Series Alarm Parameter Manual 14 Multi CPU Errors A C80 198 IB 1501279 H ...
Page 216: ...199 IB 1501279 H Parameter ...
Page 217: ...M800 M80 E80 C80 Series Alarm Parameter Manual 200 IB 1501279 H ...
Page 218: ...15 201 IB 1501279 H User Parameters ...
Page 359: ...M800 M80 E80 C80 Series Alarm Parameter Manual 15 User Parameters 342 IB 1501279 H ...
Page 360: ...16 343 IB 1501279 H Machine Parameters ...
Page 748: ......