M800/M80/E80/C80 Series Alarm/Parameter Manual
15 User Parameters
216
IB-1501279-H
[M8]
Set the minimum value of arc inside override.
R1/R2 come close to zero and the tool feed stops when the radius of tool center path(R1) is very smaller than
the radius of program path (R2).
When this parameter is set and R1/R2<=(parameter setting value), tool feed is F* (parameter setting value).
When this parameter is "0" or "100", the arc inside override is disabled.
---Setting range---
0 to 100 (%)
[C80]
Not used.
Specify the counterpart part system for timing synchronization or for balance cut when the part system No.
is omitted.
Set the part system No. in a way that reflects the combination of two part systems as follows.
(Example) Timing synchronization between Part systems 1 and 3
Enter 3 for the 1st part system, and enter 1 for the 3rd part system.
(Note) When 0 is set, timing synchronization is carried out between Part systems 1 and 2.
---Setting range---
0 to 8
[M8]
Select the enable conditions for the arc inside override.
0: Enable during tool radius compensation
1: Enable during tool radius compensation and automatic corner override
(Note) When M2 format is in use, the arc inside override enables during tool radius compensation, regardless
of the setting value of this parameter.
[C80]
Not used.
[M8]
Specify the type of arc inside override.
0: Type 1
Arc inside override during circular cutting is invalid.
1: Type 2
Arc inside override during circular cutting is valid.
[C80]
Not used.
Set a radius used as standard for the rotary axis speed.
When the setting value of #19425 is larger than that of "#19427 ManualB Std R2", #19425 setting will be used
as surface speed control standard radius 2: #19427 setting will be used as surface speed control standard
radius 1.
---Setting range---
0 to 99999.999 (mm)
#19418
Arc inside min ovr (for M system only)
#19419
Timing sync system
#19420
Arc inside ovr ON (for M system only)
#19421
Arc inside ovr typ (for M system only)
#19425
ManualB Std R1
Summary of Contents for C80 Series
Page 1: ......
Page 7: ......
Page 11: ......
Page 13: ......
Page 15: ......
Page 18: ...1 IB 1501279 H Alarm ...
Page 19: ...M800 M80 E80 C80 Series Alarm Parameter Manual 2 IB 1501279 H ...
Page 20: ...1 3 IB 1501279 H Operation Errors M ...
Page 54: ...2 37 IB 1501279 H Stop Codes T ...
Page 62: ...3 45 IB 1501279 H Servo Spindle Alarms S ...
Page 81: ...M800 M80 E80 C80 Series Alarm Parameter Manual 3 Servo Spindle Alarms S 64 IB 1501279 H ...
Page 82: ...4 65 IB 1501279 H MCP Alarms Y ...
Page 98: ...5 81 IB 1501279 H System Alarms Z ...
Page 111: ...M800 M80 E80 C80 Series Alarm Parameter Manual 5 System Alarms Z 94 IB 1501279 H ...
Page 112: ...6 95 IB 1501279 H Absolute Position Detection System Alarms Z7 ...
Page 118: ...7 101 IB 1501279 H Distance coded Reference Scale Errors Z8 ...
Page 120: ...8 103 IB 1501279 H Emergency Stop Alarms EMG ...
Page 124: ...9 107 IB 1501279 H Computer Link Errors L ...
Page 126: ...10 109 IB 1501279 H User PLC Alarms U ...
Page 136: ...11 119 IB 1501279 H Network Service Errors N ...
Page 139: ...M800 M80 E80 C80 Series Alarm Parameter Manual 11 Network Service Errors N 122 IB 1501279 H ...
Page 140: ...12 123 IB 1501279 H Program Errors P ...
Page 178: ...13 161 IB 1501279 H Smart Safety Observation Alarm V ...
Page 192: ...14 175 IB 1501279 H Multi CPU Errors A C80 ...
Page 215: ...M800 M80 E80 C80 Series Alarm Parameter Manual 14 Multi CPU Errors A C80 198 IB 1501279 H ...
Page 216: ...199 IB 1501279 H Parameter ...
Page 217: ...M800 M80 E80 C80 Series Alarm Parameter Manual 200 IB 1501279 H ...
Page 218: ...15 201 IB 1501279 H User Parameters ...
Page 359: ...M800 M80 E80 C80 Series Alarm Parameter Manual 15 User Parameters 342 IB 1501279 H ...
Page 360: ...16 343 IB 1501279 H Machine Parameters ...
Page 748: ......