M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
370
IB-1501279-H
[M8]
Select whether to enable or disable the stroke check before travel for skip (G31 or G31.n) and automatic tool
length measurement (G37).
0: Disable
1: Enable
(Note) This parameter is enabled when #12057=1 and the option "Stroke check before travel" is ON.
[C80]
Not used.
Specify each sub part system name.
This name is displayed when the part system acts as a sub part system.
---Setting range---
A combination of a maximum of four alpha-numeric characters
Select whether to enable variable-acceleration pre-interpolation acceleration/deceleration control while high-
accuracy control is ON.
0: Pre-interpolation acceleration/deceleration
(Apply the acceleration rate that is determined by G1bF and G1btL and is common for all the axes)
1: Variable-acceleration pre-interpolation acceleration/deceleration
(Apply the acceleration rate that is determined by G1bFx and G1btLx for each axis)
(Note) Variable-acceleration pre-interpolation acceleration/deceleration is a function available under SSS
control. To enable this function, set "#8090 SSS ON" to 1.
Specify the time constant of the filter that smoothes out fluctuations in acceleration under the tolerance con-
trol.
Basically set to 0.
---Setting range---
0 to 200 (ms)
Specify the axis address to be given in an arbitrary axis exchange command for the part system.
(Note 1) This parameter is disabled when the arbitrary axis exchange function is unused.
(Note 2) Do not give an identical name to two or more of the parameters adr_abs[1] to adr_abs[8].
(Note 3) Do not leave any unspecified parameter in the middle between adr_abs[1] and [8].
(Note 4) Set the addresses of adr_abs[ ] in the same order as of the axis names (#1013 axname). Note that
you can set a nonexistent axis name in the middle.
(Note 5) If there are 9 or more control axes per part system, specify the axis address that is programmed
based on the basic axis configuration.
---Setting range---
Axis address such as X, Y, Z, U, V, W, A, B and C
Specify the incremental command address for each of the axes to be used in an arbitrary axis exchange com-
mand.
(Note 1) This parameter is disabled when the arbitrary axis exchange function is unused.
(Note 2) There is no need to set this parameter when command type (absolute or incremental) is not distin-
guished by the axis address (when #1076 ABS/INC address=0).
(Note 3) Do not give an identical name to two or more of the parameters adr_inc[1] to adr_inc[8].
If there is any overlap, priority is given in the ascending order (adr_inc[1] to adr_inc[8]).
---Setting range---
Axis address such as X, Y, Z, U, V, W, A, B and C
#12058
OT_prechkTYPE
Stroke check before travel for skip and automatic tool
length measurement
#12059
SBS_name
Sub part system name
#12060
VblAccPreInt
Variable-acceleration pre-interpolation acceleration/de-
celeration ON
#12070
Sfilt2_tol
Tolerance control: Soft acceleration/deceleration filter
2
(PR)
#12071-12078
adr_abs[1]-[8]
Command address for arbitrary axis exchange
(PR)
#12079-12086
adr_inc[1]-[8]
Incremental command address for arbitrary axis ex-
change
Summary of Contents for C80 Series
Page 1: ......
Page 7: ......
Page 11: ......
Page 13: ......
Page 15: ......
Page 18: ...1 IB 1501279 H Alarm ...
Page 19: ...M800 M80 E80 C80 Series Alarm Parameter Manual 2 IB 1501279 H ...
Page 20: ...1 3 IB 1501279 H Operation Errors M ...
Page 54: ...2 37 IB 1501279 H Stop Codes T ...
Page 62: ...3 45 IB 1501279 H Servo Spindle Alarms S ...
Page 81: ...M800 M80 E80 C80 Series Alarm Parameter Manual 3 Servo Spindle Alarms S 64 IB 1501279 H ...
Page 82: ...4 65 IB 1501279 H MCP Alarms Y ...
Page 98: ...5 81 IB 1501279 H System Alarms Z ...
Page 111: ...M800 M80 E80 C80 Series Alarm Parameter Manual 5 System Alarms Z 94 IB 1501279 H ...
Page 112: ...6 95 IB 1501279 H Absolute Position Detection System Alarms Z7 ...
Page 118: ...7 101 IB 1501279 H Distance coded Reference Scale Errors Z8 ...
Page 120: ...8 103 IB 1501279 H Emergency Stop Alarms EMG ...
Page 124: ...9 107 IB 1501279 H Computer Link Errors L ...
Page 126: ...10 109 IB 1501279 H User PLC Alarms U ...
Page 136: ...11 119 IB 1501279 H Network Service Errors N ...
Page 139: ...M800 M80 E80 C80 Series Alarm Parameter Manual 11 Network Service Errors N 122 IB 1501279 H ...
Page 140: ...12 123 IB 1501279 H Program Errors P ...
Page 178: ...13 161 IB 1501279 H Smart Safety Observation Alarm V ...
Page 192: ...14 175 IB 1501279 H Multi CPU Errors A C80 ...
Page 215: ...M800 M80 E80 C80 Series Alarm Parameter Manual 14 Multi CPU Errors A C80 198 IB 1501279 H ...
Page 216: ...199 IB 1501279 H Parameter ...
Page 217: ...M800 M80 E80 C80 Series Alarm Parameter Manual 200 IB 1501279 H ...
Page 218: ...15 201 IB 1501279 H User Parameters ...
Page 359: ...M800 M80 E80 C80 Series Alarm Parameter Manual 15 User Parameters 342 IB 1501279 H ...
Page 360: ...16 343 IB 1501279 H Machine Parameters ...
Page 748: ......