bit0: Part system synchronization method
Select the part system synchronization method.
0: If one part system is not in the automatic operation, the synchronization command will be ignored and
the next block will be executed.
1: Operate according to the "waiting ignore" signal.
If the "waiting ignore" signal is set to "1", the synchronization command will be ignored. When set to "0",
synchronization will be applied.
bit1: Interrupt amount during machine lock
Select when to cancel the interruption amount during machine lock.
0: When resetting
1: During manual reference position return (not when resetting)
bit2: Selection of cutting start interlock target block
Select whether to enable the cutting start interlock for successive cutting blocks.
0: Enable
1: Disable
bit4: Dry run OFF during thread cutting
Select whether to enable or disable dry run during thread cutting.
0: Enable dry run
1: Disable dry run
bit5: Cancel G92 shift distance
Select whether to clear the G92 (coordinate system setting) shift distance when the manual reference posi-
tion is reached.
0: Not clear
1: Clear
bit6: Enable single block stop at middle point
Set whether to enable/disable single block stop at the middle point of G28/G29/G30.
0: Disable single block stop
1: Enable single block stop
bit7: Retain G52 at manual reference position return
Select whether to retain the local coordinate system setting (G52) at the time of manual reference position
arrival. This parameter is enabled when #1279 ext15/bit5 is 1.
0: Not retain (Cancel)
1: Retain
(PR)
#1279
ext15
Summary of Contents for C80 Series
Page 1: ......
Page 7: ......
Page 11: ......
Page 13: ......
Page 15: ......
Page 18: ...1 IB 1501279 H Alarm ...
Page 19: ...M800 M80 E80 C80 Series Alarm Parameter Manual 2 IB 1501279 H ...
Page 20: ...1 3 IB 1501279 H Operation Errors M ...
Page 54: ...2 37 IB 1501279 H Stop Codes T ...
Page 62: ...3 45 IB 1501279 H Servo Spindle Alarms S ...
Page 81: ...M800 M80 E80 C80 Series Alarm Parameter Manual 3 Servo Spindle Alarms S 64 IB 1501279 H ...
Page 82: ...4 65 IB 1501279 H MCP Alarms Y ...
Page 98: ...5 81 IB 1501279 H System Alarms Z ...
Page 111: ...M800 M80 E80 C80 Series Alarm Parameter Manual 5 System Alarms Z 94 IB 1501279 H ...
Page 112: ...6 95 IB 1501279 H Absolute Position Detection System Alarms Z7 ...
Page 118: ...7 101 IB 1501279 H Distance coded Reference Scale Errors Z8 ...
Page 120: ...8 103 IB 1501279 H Emergency Stop Alarms EMG ...
Page 124: ...9 107 IB 1501279 H Computer Link Errors L ...
Page 126: ...10 109 IB 1501279 H User PLC Alarms U ...
Page 136: ...11 119 IB 1501279 H Network Service Errors N ...
Page 139: ...M800 M80 E80 C80 Series Alarm Parameter Manual 11 Network Service Errors N 122 IB 1501279 H ...
Page 140: ...12 123 IB 1501279 H Program Errors P ...
Page 178: ...13 161 IB 1501279 H Smart Safety Observation Alarm V ...
Page 192: ...14 175 IB 1501279 H Multi CPU Errors A C80 ...
Page 215: ...M800 M80 E80 C80 Series Alarm Parameter Manual 14 Multi CPU Errors A C80 198 IB 1501279 H ...
Page 216: ...199 IB 1501279 H Parameter ...
Page 217: ...M800 M80 E80 C80 Series Alarm Parameter Manual 200 IB 1501279 H ...
Page 218: ...15 201 IB 1501279 H User Parameters ...
Page 359: ...M800 M80 E80 C80 Series Alarm Parameter Manual 15 User Parameters 342 IB 1501279 H ...
Page 360: ...16 343 IB 1501279 H Machine Parameters ...
Page 748: ......