M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
461
IB-1501279-H
Set the non-sensitive band to be used for judging the manual measurement direction. If the feedback position
fluctuates widely at the axis stop, set the fluctuation width or larger value in this set the parameter.
When set to "0", the band will be 1 (µm).
---Setting range---
0 to 1000 (µm)
0: 1 (µm)
[M8]
Select the machining surface indexing type in the R-Navi function.
0: Indexing type 1 (Only rotary axes move to perform indexing)
1: Indexing type 2 (Indexing is performed with the tool center point fixed to the position seen from the work-
piece)
[C80]
Not used.
Select the T display (tool command value) type on the monitor screen between displaying tool No. only or
displaying tool No. and compensation No. (L system only)
0: Display tool No. only
1: Display the tool command value (the combined value consisting of the tool No. and compensation No.)
last commanded by the program. Even in a manual value command, the program's tool command value
is displayed.
Set the availability of the cursor position search during single block stop when #11031 Cursor pos search=1
to 3.
0: Disable cursor position search during single block stop.
1: Enable cursor position search during single block stop.
Sub-program is displayed when selecting menus [Monitr]-[Edit] while single block stop is carried out during
sub-program with this parameter set to 1.
[M8]
Select ON/OFF of the Direct Socket communication I/F.
0: OFF (Default)
1: ON
(Note) When the Direct Socket communication I/F is ON, applications that uses "#1926 Global IP address"
such as MS Configurator and GX Developer cannot be used.
[C80]
Not used.
Select in which order to sort the operation log files (all logs) to be output.
0: Sort the data in chronologically ascending order separately for each log type.
1: Sort the data in chronologically ascending order for all the log types.
If the times and dates logged are identical, the log files are output in the order of key, touchscreen, alarm,
PLC signal, tool offset change, workpiece offset change and AC power.
Specify which magazine to display when Sp-stby is selected on the Spindle standby or Tool registration
screen.
0: Fixed to the magazine #1
1: The magazine selected by the menu (Magazine 1 to Magazine 5).
#11036
meas dir judge
Non-sensitive band for manual measurement direction
judgment (for M system only)
#11037
R-Navi Index Type
R-Navi machining surface indexing type
#11038
T disp typ
T display (tool command value) type (For L system only)
#11039
Cusr pos srch type
Cursor position search type
#11051
Direct Socket ON
Direct Socket communication I/F ON
#11052
LOG Sort Order
Log data sorting order
#11054
Sp-stby disp type
Spindle-standby display type
Summary of Contents for C80 Series
Page 1: ......
Page 7: ......
Page 11: ......
Page 13: ......
Page 15: ......
Page 18: ...1 IB 1501279 H Alarm ...
Page 19: ...M800 M80 E80 C80 Series Alarm Parameter Manual 2 IB 1501279 H ...
Page 20: ...1 3 IB 1501279 H Operation Errors M ...
Page 54: ...2 37 IB 1501279 H Stop Codes T ...
Page 62: ...3 45 IB 1501279 H Servo Spindle Alarms S ...
Page 81: ...M800 M80 E80 C80 Series Alarm Parameter Manual 3 Servo Spindle Alarms S 64 IB 1501279 H ...
Page 82: ...4 65 IB 1501279 H MCP Alarms Y ...
Page 98: ...5 81 IB 1501279 H System Alarms Z ...
Page 111: ...M800 M80 E80 C80 Series Alarm Parameter Manual 5 System Alarms Z 94 IB 1501279 H ...
Page 112: ...6 95 IB 1501279 H Absolute Position Detection System Alarms Z7 ...
Page 118: ...7 101 IB 1501279 H Distance coded Reference Scale Errors Z8 ...
Page 120: ...8 103 IB 1501279 H Emergency Stop Alarms EMG ...
Page 124: ...9 107 IB 1501279 H Computer Link Errors L ...
Page 126: ...10 109 IB 1501279 H User PLC Alarms U ...
Page 136: ...11 119 IB 1501279 H Network Service Errors N ...
Page 139: ...M800 M80 E80 C80 Series Alarm Parameter Manual 11 Network Service Errors N 122 IB 1501279 H ...
Page 140: ...12 123 IB 1501279 H Program Errors P ...
Page 178: ...13 161 IB 1501279 H Smart Safety Observation Alarm V ...
Page 192: ...14 175 IB 1501279 H Multi CPU Errors A C80 ...
Page 215: ...M800 M80 E80 C80 Series Alarm Parameter Manual 14 Multi CPU Errors A C80 198 IB 1501279 H ...
Page 216: ...199 IB 1501279 H Parameter ...
Page 217: ...M800 M80 E80 C80 Series Alarm Parameter Manual 200 IB 1501279 H ...
Page 218: ...15 201 IB 1501279 H User Parameters ...
Page 359: ...M800 M80 E80 C80 Series Alarm Parameter Manual 15 User Parameters 342 IB 1501279 H ...
Page 360: ...16 343 IB 1501279 H Machine Parameters ...
Page 748: ......